
Installation Instructions
5-16
Configurable Zone Type Programming (*83 Menu Mode)
Start Configurable Zone Type Programming Mode by pressing
∗
83 while in Data Programming mode.
E n t e r Z o n e T y p e
( 0 0 = q u i t ) 9 0
Zone Type Number
90-93 = zone type
[
∗
] to continue
Enter the configurable zone type number being programmed.
9 0 Z n A t t r i b u t e s
0
Zone Attributes
0 = none
1 = exit delay only
2 = entry/exit 1
3 = entry/exit 2
4 = follows entry/exit
5 = has verification (resets
power upon event and when
code + OFF to clear condition. If
condition persists, zone
activates)
6 = resettable (upon code +
OFF)
[
∗
] to continue
Enter the desired zone attributes.
9 0 B y p a s s O p t i o n
0
Bypass Option
0 = zone type cannot be
bypassed
1 = auto bypassed when armed
in stay mode
[
∗
] to continue
Enter the desired bypass option.
9 0 R e s p t o S h o r t
A r m e d 0 D A r m d 0
Response to Shorts
0=none 2=trouble
1=Alarm 3=fault
[
∗
] to continue
Select the type of response when zones assigned to this zone type are
shorted when the system is armed.
NOTES:
1. For double-balanced zones, this entry must be 0.
2. For zone-doubled zones,
both
zones of the doubled pair
must be assigned the same response to a short.
9 0 R e s p t o o p e n
A r m e d 0 D A r m d 0
Response to Opens
0 = none
2 = trouble
1 = Alarm
3 = fault
[
∗
] to continue
Select the type of response when zones assigned to this zone type are
opened when the system is armed.
9 0 V e n t Z o n e
0 = N o , 1 = Y e s
Vent Zone?
0=no
1=yes
[
∗
] to continue
If selected, the system can be armed even if zones assigned to this
zone type are faulted.
NOTE:
After arming, faults on these zones will be ignored until the
zone is restored.
9 0 A l m / T r b l P r o c
0
Alarm/Trouble
Processing
0=none
1=Zone type has automatic
restore
2=zone type uses Misc. Fault
Delay Time and automatic
restore
[
∗
] to continue
Select desired actions for zones assigned to this zone type.
Option 2: Select Miscellaneous Fault Delay in field *87.
9 0 T R B L S O U N D
0
Trouble Sounding
0= none
1= one beep every minute
2= normal trouble sound (fast
beeps)
[
∗
] to continue
Select type of sounding upon trouble conditions on zones assigned to
this zone type.
9 0 A L A R M S O U N D
0
Alarm Sounding
0=none
1= keypad sound only
2= steady siren sounding
3= pulsing siren (temporal)
[
∗
] to continue
Select type of sounding upon alarm conditions on zones assigned to
this zone type.
Summary of Contents for Ademco Vista-48LA
Page 1: ...ADEMCO VISTA 48LA Security System Installation and Set Up Guide K0749 6EN 5 05 Rev A ...
Page 2: ...ii ...
Page 28: ...Installation Instructions 3 8 ...
Page 42: ...Installation Instructions 4 14 ...
Page 62: ...Installation Instructions 5 20 ...