80 Device Programming Menu Mode
STOP
The "STOP" programming determines when and under what conditions the device will be de-
activated. The following options are available:
Upon Restore of a Zone List
Restore Zone List: If a "ZONE LIST" is used as the “Stop” event, the device will de-activate when
all
the
zones in that list restore from a previous fault, trouble, or alarm condition. This will occur regardless of
what is programmed to "START" the device; therefore, a "RESTORE ZONE LIST" would normally only be
used when a "ZONE LIST" is used to start the device.
Upon a Zone Type or System Operation
Zone Type/System Operation: Instead of using a "RESTORE ZONE LIST," a specific zone (response) type or
system operation action can be selected to de-activate the device.
•
If a specific "ZONE TYPE" is chosen,
any zone of that response type that restores from a previous alarm,
trouble, or fault condition will cause the device to de-activate.
•
If a "SYSTEM OPERATION" is chosen, that operation will cause the device to de-activate.
During normal system operation,
any devices may be manually started by keypad entry of:
Code* + [#]
+ 4 + “n;”
or manually stopped by keypad entry of:
Code* + [#] + 7 + “n,”
where “n” = the device number to
be controlled.
* Code is required for devices 7 and 8. For devices 1-6, code is not required. See User Manual for more
information.
Programming Powerline Carrier Devices
While in program mode, press
✻
80 to enter Output Device Menu Mode.
This mode is used to program
all output devices used in the system. Refer to the output device table for
✻
80 on the separate programming
form when programming output devices.
Note:
The House ID of the Powerline Carrier Devices must be entered in data field
✻
25.
The prompts for
✻
80 are as follows:
80
Powerline Carrier Device Programming Main Menu prompt
A 01
Device Number --------- for entering the device number
b
Device Action ------------ for defining the action the device will perform when active
C
Start Event Type ------- for assigning the event type to start the action
d
Start Zone List ---------- for assigning the zone list to start the action
E
Start Zone Type--------- for assigning the zone type to start the action
F
Stop Zone List ----------- for assigning the zone list to stop the action
1A
Stop Zone Type---------- for assigning the zone type to stop the action