2
DIP Switch Settings
Normal operation of the 5843 requires all DIP switches be in
the OFF position.
DIP switch 1 – Enables the
Erasing All RF Transmitters Mode
.
Refer to Erasing All RF Transmitters Section.
DIP switch 2 – Enables the
Enrolling RF Transmitters Mode
.
Refer to Enrolling RF Transmitters Section.
DIP switch 3 – Used during
Enrolling RF Transmitters Mode
.
Refer to Enrolling RF Transmitters section.
DIP switch 4 – 6 Used during
Erasing All RF Transmitters
2
3
4
5
6
1
ON
OFF
5800GDO-002-V0
ENROLLING RF TRANSMITTERS
Notes:
•
To exit the Transmitter Enrollment Mode at any
time, set DIP switch 2 to the OFF position.
•
Unless otherwise noted, the 5843 will automatically
exit the Transmitter Enrollment Mode if each step is
not accomplished within one minute of the other.
•
If during the enrollment procedure excessive RF
interference is noted as indicated by the RF
Interference Indicator LED, it is advised that
enrollment be exited until free of RF interference.
This will prevent inadvertent enrollment of an
outside wireless transmitter device.
1.
Set all DIP switches to the OFF position.
2.
Place DIP switch 2 in the ON position.
3.
Disconnect/reconnect power to the 5843.
Immediately after power is applied the following will
occur:
•
The green LED will turn on and remain on.
•
If the EEPROM is not full, the red LED will flash on
and off once for each transmitter that can still be
enrolled and
then
lights steady.
•
If the EEPROM is full (8 wireless keys enrolled), the
red LED will remain on, indicating that no more
transmitters can be enrolled.
4.
If enrolling…
Do this…
An encrypted
transmitter (i.e.
5804E and
5804WATCH)
Press and hold all 4 buttons at
the same time. Verify that the
red LED turns off.
A bi-directional
encrypted
transmitter (i.e.
5804BDV)
Press and hold the B, C, & D
buttons at the same time.
Verify that the red LED turns
off.
A non-encrypted
transmitter (i.e.,
5804, 5804BD)
Press the button to be enrolled
twice. Verify that the red
LED turns off.
5.
Place DIP switch 3 in the ON position.
6.
Press and release the button that will be used to
operate the switch. Verify the red LED flashes 3
times.
Note
: If an incorrect wireless transmitter is enrolled,
set DIP switch 3 to OFF and repeat the enrollment
procedure from step 4.
7.
To add an additional button on the same key, repeat
step 6 for that button.
8.
Place DIP switch 3 in the OFF position to accept the
button(s) enrolled.
9.
Repeat steps 4 through 8 to enroll additional
wireless transmitters.
10.
When all devices are enrolled, place DIP switch 2 in
the OFF position.
ERASING ALL RF TRANSMITTERS
Notes:
•
To exit this procedure at any time, set DIP switch 1
to the OFF position and wait 5 seconds before
restarting procedure.
•
Unless otherwise noted, the 5843 will automatically
exit the
Erasing All RF Transmitters Mode
if each
step is not accomplished within one minute of the
previous step.
1.
Place DIP switch 1 in the ON position.
2.
Disconnect/reconnect power to the 5843.
Immediately after power is applied the following will
occur:
•
The green LED will turn on and remain on.
•
If the EEPROM is not full, the red LED will flash on
and off once for each transmitter that can still be
enrolled and
then
lights steady.
•
If the EEPROM is full (8 wireless keys enrolled), the
red LED remain on, indicating no more transmitters
can be enrolled.
3.
Place all DIP switches opposite to their current
position within one minute of applying power in step
2. (All DIP switches must be switched opposite to
their current position within 5 seconds of each other
to avoid exiting this procedure.)
4.
Return all DIP switches to their original positions
and verify the red LED turns off.
When the red LED turns off, all transmitters have
been erased.
SPECIFICATIONS
Dimensions:
2-3/4” W x 4-15/16” H x 1-1/16” D.
(70mm x 125mm x 27mm)
Voltage:
12VDC OR
9VAC, 15VA (use ADEMCO 1332 or equivalent)
Current:
60mA
Relay:
One relay, with choice of normally open or normally
closed operation.
Contact Ratings: 2 Amps at 28VDC.
Operating Temperature:
32
°
- 122
°
F (0
°
- 50
°
C)