21
4.
Mounting
The reader is suitable for indoor and outdoor use. Mount directly on the wall or use a "standard f.m.
socket". The electronic unit is inserted in the back of the housing and locked into position with the
housing front (replaceable).
For mounting surfaces of metal, the transmission range of the data carrier may be lower
than that of non-metallic surfaces.
In order to operate and read the keypad/indication optimally, install the reader at a
height of 130 to
140 cm
above the floor.
When used outdoors, do not expose the reader directly to the weather!
If necessary, use the plastic housing (weather/view) Item no. 023501.
To mount, lift the housing front at the bottom and unhook at the top. When installing the housing back,
remove the electronics to avoid damage.
The housing back has two 60 mm boreholes for wall and f.m. sockets. To fix securely, use screws that
are suitable for the mounting surface in question.
-
In masonry with S6 plug:
E.g. semi-circular wood screw with slot 3.5 x 60 mm
-
In wood, depending on type: Semi-circular wood screw with slot 3.5 x 45 to 3.5 x 60 mm
-
In metal:
Fillister head screw M3 x 30 mm (min.) with washer
-
On the standard s.m. socket
Semi-circular wood screw with slot 3.0 x 40 mm and washer
For additional fixing, the third borehole can be used. Choose the correct screw length for the
mounting surface.
When mounting, feed the connecting cable, if possible, from the back through an empty pipe
allowing sufficient spare cable.
When mounting on an f.m. socket or on a cavity wall, install the socket so that the fixing holes are
horizontal (see illustration).
Attention!
If the reader is to be used outdoors, the cable bushing must be sealed
on both sides
of
the wall, (e.g. with plaster
)
to prevent condensation from forming!
To
lock the housing
press in one of the
enclosed seals at the bottom. The housing
cannot be opened without destroying the
seal.
60 mm
Fixing holes
f.m. socket (DIN)
Observe notches
VdS
The dimensions of readers with and without keypad are identical.
Dimensions (in mm)
F
i
2
3
6
5
4
7
8
9
0
r
1
75
32
142
60
54
46,5
69,5
134,5
100,5
Housing back
without electronics
Cable entry
3
Mounting and Connection Instructions mifare/DESFire EV1 reader "Accentic" with/without keypad