3 - 17
Operating Temperature
14° to122°F (-10° to 50°C)
Charging Temperature
32° to 113°F (0° to 45°C)
Storage Temperature
-4° to 158°F (-20° to 70°C)
Humidity
95% humidity, non-condensing
Construction
High impact resistant PC/ABS housings
Magnesium alloy internal chassis with component shock mounts
Drop
4 ft. (1.2m) multiple drops to concrete, all axis, across operating temperature range
Tumble
250 3.3 ft (1.0m) tumbles per IEC 600068-2-32
ESD
Air:
± 15k Vdc
Direct:
± 8k Vdc
Environmental Sealing
IP54 rating
Dimensions
200 mm long x 83 mm wide x 42 mm deep (7.87” x 3.27” x 1.65”)
Weight
595 g (21 oz) with standard battery
Scanner / Decode
Capabilities
5300SR 2D Imager with Adaptus Technology and Laser Aimer. Decodes all standard 1D,
2D, Postal, and OCR codes.
Regulatory and
Compliance
Safety:
UL60950-1, cUL 60950
Summary of Contents for 5900 RFID