background image

Excluding the SSA1 Siren/Strobe module 

!

 

This  procedure  may  ONLY  be  used  in  the  event  that  the  SSA1  Siren  is  not  operating  properly,  has  lost 
communication with the control or if the 5877 Relay Receiver has been replaced. 

 

 

ACTION 

NOTES 

1.  At the Home or Dashboard screen select the “Automation” icon. 

Note:

 Depending upon  the control panel  that  is  being  connected  the  Garage 

Door  Setup  icon  is  located  on  either  the  first  or  second  page  of  the 
Automation Screen. 

2.  Select the Garage door setup icon. 
3.  Select the desired Garage door, from the displayed list. 
4.  At the Garage Door setup screen, select Exclude Siren **” to exclude the 

SSA1 siren/strobe module. 

5.  The panel displays “Entering Exclusion Mode. Please wait…” followed by 

“Ready  to  Exclude  device.”  Press  the  function  button  on  device.”  Within 
one minute press the siren’s Function button. 

6.  If  the  module  has  been  successfully  excluded,  the  panel  displays  the 

device information. 

Note:

  If  the  SSA1  is  shared  with  additional  garage  doors  it  will  be  excluded 

from each of those doors. 

7.  Select the “

” button to return to the Automation screen. 

8.  Include the SSA1 by repeating steps 8-11 of the “Enrolling the 5877 Relay 

Receiver and Including the SSA1 Siren/Strobe module” above. 

  If  a  single  SSA1  Siren/Strobe  Module  that  has 

been  included  on  multiple  garage  doors  is 
excluded,  it  will  be  excluded  from  ALL  garage 
doors that it had previously been included with. 

 

 

Garage Door Feature Operation 

ACTION 

NOTES 

1.  At the Home or Dashboard screen select the “Automation” icon. 
2.  At the Automation Screen, select the Garages icon. 
3.  Select  the  Garage  door  that  you  wish  to  control/program  from  the 

displayed list. The control advances to the Garage Door operation screen. 

4.  Refer  to  the  procedures  below  for  additional  operation/programming 

information. 

  The  Garage  Zone  and  Response  Type  must  be 

assigned in order to view garage door status. 

Control Panel Garage Door Opener Operation 

Ready To Arm

5200-100-128-V0

Garage Door 1

OPENED

Press to close

Edit

Back

Close in

Close at

 

Ready To Arm

lyric-069-V0

Edit

Close at

Press to close

Not Applicable to Lync Gateway

Close in

 

LYNX Touch 

Lyric Controller/Lyric Gateway

 

Garage Door Operation Screens 

Button or Icon

 

Function 

Edit

 

Used to modify description of Garage Door 

Close in* 

 

Provides access to keypad used to set a specific period of time (up to 12 hours and 59 minutes) 
before an open garage door closes automatically. If programmed the time will also be displayed. 

Close at*

 

Provides access to keypad used to set a specific time that an open garage door closes 
automatically. If programmed the time will also be displayed. 

Back

 

Used to return the control to the Garage Door list. 

  OR   

 

Press to open

 

Indicates Garage Door is Closed. Used to Open Garage Door.

 

  OR   

 

Press to close

 

Indicates Garage Door is Open. Used to Close Garage Door.

 