CAUTION: Carbon Monoxide Gas and its Detection 

This carbon monoxide alarm is designed for indoor use only. Do not 
expose to rain or moisture. Do not knock or drop the alarm. Do not 
open or tamper with the alarm as this could cause malfunction. The 
5800COA will not protect against the risk of carbon monoxide 
poisoning if not properly installed. It will only indicate the presence of 
carbon monoxide gas at the sensor.  

 

Carbon monoxide gas may be present in other areas. 
This carbon monoxide alarm is NOT: 
• Designed to detect smoke, fire or any gas other than carbon 

monoxide 

• To be seen as a substitute for the proper servicing of fuel-burning 

appliances or the sweeping of chimneys. 

• To be used on an intermittent basis, or as a portable alarm for the 

spillage of combustion products from fuel-burning appliances or 
chimneys. 

 

Carbon monoxide gas is a highly poisonous gas which is released 
when fuels are burned. It is invisible, has no smell and is therefore 
impossible to detect with the human senses. Under normal conditions 
in a room where fuel burning appliances are well maintained and 
correctly ventilated, the amount of carbon monoxide released into the 
room by appliances should not be dangerous. 

 

Symptoms of carbon monoxide poisoning: 

Carbon monoxide 

bonds to the hemoglobin in the blood and reduces the amount of 
oxygen being circulated in the body. The following symptoms are 
related to carbon monoxide poisoning and should be discussed with 
all members of the household: 
Mild exposure: Slight headache, nausea, vomiting, fatigue (often 
described as “flu-like” symptoms). 
Medium exposure: Sever throbbing headache, drowsiness, confusion, 
fast heart rate. 
Extreme exposure: Unconsciousness, convulsions, cardio respiratory 
failure, death. 
Many causes of reported carbon monoxide poisoning indicate that 
while victims are aware that they are not well, they become so 
disoriented that they are unable to save themselves by either exiting 
the building or calling for assistance. 
Also young children and pets may be the first to be affected. 

 

!

 

WARNING: IMPORTANT INFORMATION FOR THE USER 

 

Actuation of your CO alarm indicates the presence of carbon 
monoxide (CO), which can cause injury or death.  

 

Individuals with medical problems may consider using warning 
devices which provide audible and visual signals for carbon monoxide 
concentrations under 30ppm. 

 

What to do if the 5800COA goes into alarm: 

1.  Push the Hush/Test button. If the alarm reactivates or the alarm 

does not silence, continue with step 2. 

2.  Immediately move to fresh air, outdoors or by an open window. 

Check that all persons are accounted for. Do not reenter the 
premises nor move away from the open door/window until 
emergency service responders have arrived. 

3.  Call your local fire department from a phone in an area where the 

air is safe. 

4.  If your alarm reactivates within a 24-hour period, repeat steps 1-3 

and call a qualified appliance technician to investigate for sources 
of CO from fuel burning equipment and appliances, and inspect 
for proper operation of this equipment. If problems are identified 
during this inspection, have the equipment serviced immediately. 
Note any combustion equipment not inspected by the technician 
and consult the manufacturer’s instructions, or contact the 
manufacturers directly, for more information about CO safety and 
this equipment. Make sure that motor vehicles are not, and have 
not been, operating in an attached garage or adjacent to the 
residence. 

 

IMPORTANT: 

The 5800COA should be tested and maintained 

regularly following CSA 6.19-01 requirements. (Generally it should be 
tested at least once per month.) 

 

MAINTENANCE 

Occasionally clean the outside casing with a cloth. Ensure that the 
holes on the front of the alarm are not blocked with dirt and dust. 

Do not paint, and do not use cleaning agents, bleach, or polish 
on the alarm. 

 

5800COA REPLACEMENT 

The 5800COA is manufactured with a long-life carbon monoxide 
sensor. Over time the sensor will lose sensitivity, and will need to be 
replaced with a new carbon monoxide alarm. The 5800COA lifespan 
is approximately six years from the date of manufacture. 

 

The user should periodically check the device’s replacement date. 
Remove the unit from its base and check the replacement date label 
on the underside of the unit. The label indicates the date it should be 
replaced. 

 

NOTE:

 When the unit is removed from its base, a message is sent to 

the central station.  

 

The 5800COA will also cause a trouble condition once it has reached 
the end of its useful life. If this occurs, it is time to replace the alarm. 

 

NOTE: 

Before replacing the alarm, notify the proper authorities that 

maintenance is being performed and the system will be temporarily 
out of service. Disable the zone or system undergoing maintenance to 
prevent any unwanted alarms. Dispose of the 5800COA in accordance 
with any local regulations. 

 

CAUTION 

It should be noted the installation, operation, testing and 
maintenance of the 5800COA is different than smoke alarms. Per 
CSA 6.19-01 the alarm shall not be connected to a zone that signals a 
fire condition (i.e. fire zones). Therefore, the 5800COA must be 
programmed as a non-fire zone. See the control’s Installation 
Instructions for the appropriate carbon monoxide zone type to be 
programmed. 

 

SPECIFICATIONS 

Power Source: 

One 3-volt CR123A Lithium Battery 
(included). (Replace with Duracell 
DL123A, Panasonic CR123A or 
ADEMCO 466.) 

Audible Signal (temp 4 tone):  85 dBA min. in alarm (at 10ft) 

Height: 

2.3 inches (58 mm) 

Diameter: 

5.3 inches (135 mm) with mounting 
base 

Weight: 

7 oz. (241 g) without battery 

Operating Ambient  
Temperature Range: 

32° to 100°F (0° to 37.8°C)   

Operating Humidity Range:  15% to 95% Relative Humidity, non-

condensing 

Agency Listings: 

ULC Listed (test to CAN/CSA 6.19-01) 

Patent numbers:  

7,120,795

 

 

Please see insert for Limitations of Carbon Monoxide Alarms. 

 

This device complies with RSS210 of Industry Canada. Operation is 
subject to the following two conditions:  (1) This device may not 
cause harmful interference, and (2) This device must accept any 
interference received, including interference that may cause 
undesired operation. 

 

Unauthorized changes or modifications could void the user’s 
authority to operate the equipment. 

 

FOR WARRANTY INFORMATION AND FOR DETAILS REGARDING 
THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, GO TO: 

www.honeywell.com/security/hsc/resources/wa 

 

 

 

ÊK14631-1@Š 

K14631-1 10/08  Rev. B 

 

2 Corporate Center Drive, Suite 100

P.O. Box 9040, Melville, NY 11747

Copyright © 2008 Honeywell International Inc.

www.honeywell.com/security

 

 

Summary of Contents for 5800COA

Page 1: ... specified under TESTING THE 5800COA NOTE This device is designed to protect individuals from the acute effects of carbon monoxide exposure It will not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Installation of the 5800COA cannot substitute for proper installation use and maintenance of fuel burning appliances including appropriate venti...

Page 2: ...e Figure 4 for suggested detection locations and a strong wireless transmission path Proper Carbon Monoxide Detection Location In a wall location the 5800COA should be at least as high as a light switch and at least six inches from the ceiling In a ceiling location it should be at least 30cm from any wall Where to install ideally Within 2 meters of all sleeping areas Inside the bedroom if it conta...

Page 3: ...VOIR LE MANUEL 1 BEEP SEE OWNER S M A N U A L A V E R T I S S E U R D E M O N O X Y D E C A R B O N M O N O X I D E A L A R M D E C A R B O N E A V E R T I S S E M E N T E N A L A R M E S E R E N D R E À L A I R F R A I S A P P E L E R 9 1 1 A D D I T I O N A L M ARKINGS ON BACK C AUTION M I S E E N G ARDE LIRE À ARRIERE W A R N I N G I N A L A R M M O V E T O F R E S H A I R C A L L 9 1 1 PUSH RE...

Page 4: ...ion equipment not inspected by the technician and consult the manufacturer s instructions or contact the manufacturers directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence IMPORTANT The 5800COA should be tested and maintained regularly following CSA 6 19 01 requirements ...

Reviews: