4 - 22
Scan
Discard Partial Sequence
to discard partial sequences when the
output sequence operation is terminated before completion. Scan
Trans-
mit Partial Sequence
to transmit partial sequences. (Any fields in the
sequence where no data match occurred will be skipped in the output.)
Require Output Sequence
When an output sequence is
Required
, all output data must conform to an
edited sequence or the scanner will not transmit the output data to the host
device. When it’s
On/Not Required
, the scanner will attempt to get the
output data to conform to an edited sequence but, if it cannot, the scanner
transmits all output data to the host device as is.
When the output sequence is
Off
, the bar code data is output to the host as
the scanner decodes it.
Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Multiple Symbols
When this programming selection is turned
On
, it allows you to read multiple
symbols with a single pull of the scanner’s trigger. If you press and hold the trig-
ger, aiming the scanner at a series of symbols, it reads unique symbols once,
beeping (if turned on) for each read. The scanner attempts to find and decode
Transmit Partial Sequence
* Discard Partial Sequence
Required
On/Not Required
*Off
Summary of Contents for 1900GSR-2
Page 1: ... Xenon 1900 1902 Area Imaging Scanner User s Guide ...
Page 60: ...2 28 ...
Page 94: ...3 34 ...
Page 136: ...6 12 ...
Page 212: ...8 20 ...
Page 220: ...9 8 ...
Page 226: ...10 6 ...
Page 274: ...12 8 ...
Page 280: ...13 6 ...
Page 291: ......
Page 292: ......
Page 295: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...
Page 296: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Page 298: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 Xenon UG Rev B 6 10 ...