9.5.1 General functions
FAI logic:
The FAI connections of all detectors are connected to one another. A connection to the control
panel is not required. The LED flashes on the detector that triggers first, the LED light on the
subsequently triggered detectors is static (see 9.4.1).
Contacts:
Alarm
Contact open in the event of an alarm
Fault
Contact open in the event of a fault
Tamper
Contact open in the event of tamper
Backtamper and tamper are both switched to the tamper output.
To comply with VdS and EN 50131-2-2, connect this output to a tamper detector group at the control panel.
Mounting and Connection Instructions Viewguard PIR / AM FAI
Function of inputs:
(Pull-up resistors in the detector)
Function
armed
armed
disarmed
walk test
High
Low
Inputs
walk test disarmed
High
High
Low
Low
Low
High
9.5.3 Operating mode "SCM 3000 compatible"
f
or operation with MB-control panel series
DIP switch setting see table in Chapter 9.1
The input
has the function "
". Details see Installation Instructions of the control panel.
Difference between operating mode "Viewguard":
"Walk test" (T)
Clear
Fault Tamper Alarm
If the control panel has no fault input, the "Alarm" and "Fault" outputs can be connected
in series.
Fault Tamper Alarm T U F
- +
Fault Tamper Alarm T U F
- +
Detector 1
up to max. detector 20
FAI
Fault
Alarm
Tamper
W
alk test
disarmed
F
AI
0 V
+12 V DC
Fault
Alarm
Tamper
W
alk test
disarmed
F
AI
0 V
+12 V DC
+12 V DC
0 V
walk test
disarmed
shield
IDS
Control panel
alarm
detector zone
tamper
detector zone
Bases e.g. for
end of line
resistors
Bases e.g. for
end of line
resistors
End of line resistors in the last
detector. The value depends
on the control panel.
Alarm end of line resistor
Tamper end of line resistor
Fault Tamper Alarm T U F
- +
FAI
Fault
Alarm
Tamper
clear
disarmed
F
AI
0 V
+12 V DC
+12 V DC
0 V
clear
disarmed
shield
IDS
Control panel
alarm
detector zone
tamper
detector zone
Bases e.g. for
end of line
resistors
9.5.2 Operating mode "Viewguard"
DIP switch setting see table in Chapter 9.1
Apart from that, the connection diagram of the operating mode "Viewguard" is
applicable (see above).
Function
armed
armed
disarmed not cleared
disarmed cleared, walk test
High
Low
Inputs
clear
disarmed
High
High
Low
Low
High
The Walk test function remains "on" until next arming.
Low (pulse)
Function of inputs:
(Pull-up resistors in the detector)
Clear alarm memory: Activate and
deactivate walk test.
Detector 1
FAI
Detector 2
Detector 3
Detector 20
FAI
FAI
FAI