12
Mounting and Connection Instructions Viewguard PIR / AM FAI
7.4
Cable entry, strain relief
7.5
Fix housing base
Backtamper
Pin for activating the
tamper
Hole for fixing the
backtamper
Screw down the housing
base at point (c) when
using the backtamper. If
the detector is torn off the
wall, part breaks off and
the tamper triggers.
3
a
3
b
3
c
Fig. 10
1
4
4
2
3
3
7.6
Backtamper
Please note, that backtamper is not possible when mounting according
to Fig. 7/3a and 7/3c.
When installed in accordance with VdS systems class B
and C, the backtamper must be used.
The method of attachment of
the housing base depends on
installation according to Fig. 7:
(Fig. 7/1)
Screw on position
.
(Fig. 7/2)
Screw on position
.
(Fig. 7/3)
Screw on position
or
,
depending on direction.
(Fig. 7/4)
Screw on position
.
Only fix the housing base on
one side with 2 screws.
When screwing down the
back with 4 screws, it may
become taught and the front
of the housing may no lon-
ger fit.
- 0° Vertical
- 3° Vertical
- 45° Horizontal to the left or
right
- Corner mounting
1
2
3
4
3
4
or
The mounting on adjustable and ball-and-socket joints is
described in the respective instructions.
Fig. 9
3
B
3
C
3
B
3
A
3
C
3
D
3
D
Fig. 11
3
b
3
c
3
a
For s.m. wiring
For f.m. wiring
For strain relief with
cable strap
For use with Adjus-
table joint
3
A
3
C
3
D
3
B
3
D
+
7.3
Mounting possibilities
(Fig. 7 and 8)
-
0° Vertical at a 0° downward angle (Fig. 7/1)
-
3° Vertical at a 3° downward angle (Fig. 7/2)
-
45° Horizontal at a 45° angle to the left or right (Fig. 7/3)
-
Corner mounting (Fig. 7/4)
7.3.1 Mounting directly on the wall
Fig. 8
0
°
45°
45°
8/2
8/3
+4°
-8°
± 20
°
8/1
Adjustable joint
7.3.2 Mounting on Adjustable joint
(Item no. 033390.17, see 11. "Accessories")
Should the mounting possibilities in accordance with Fig. 7 not suffi-
ce, the detector can be mounted on the "Adjustable joint".
Swivel range: ±20° horizontal, +4° to -8° vertical.
Depending on the setting the Detection coverage changes
(Details see Chapter 6. "Detection coverage").
The adjustable joint is not provided with a backtamper.
For the installation in VdS systems of class B and C, a solid
basis with the defined inclination is required on site to ensure
proper functioning of the backtamper.
-
Mounting directly on the wall (Fig. 8/1)
-
Horizontal at a 45° angle to the left or right (Fig. 8/2)
-
Corner mounting (Fig. 8/3)
Note:
Mounting possibilities:
7.3.3 Mounting on Ball-and-socket set
(Item no. 033588.17, see 11. "Accessories")
The Ball-and-socket set provides the most versatile adjustment
possibilities.
Swivel range: ±45° horizontal, ±20° vertical.
Mounting on Ball-and-socket set not as per VdS and EN.
Fig. 7
Backtamper here (a and c) not possible
+/-0
°
45
°
45
°
7/1
7/2
7/3
7/4
a)
b)
c)