Mounting and Connection Instructions TouchCenter Keypad BUS-2
11
4. General
The operating and display panel TouchCenter supplements the intruder alarm control panels
561- MB100 / HB48 / MB48 / MB24 / HB24 and also MB256 plus. The connection to the operating
and display panel required a BUS-2 connection. The TouchCenter panel also enables information
on the system state to be displayed decentrally in a clear and comprehensive manner.
Information on status and operation is displayed clearly. You can operate the system in a dialog-
managed manner.
Project-related programming of the intruder alarm control panel as well as the operating and display
panel TouchCenter is carried out per PC/laptop using the software package “WINFEM Advanced”.
WINFEM Advanced
Type of control panel
Version 1.xx
MB100.10 / HB48.10 / MB48 / MB24 / HB24 all from V05.xx
Version 6.xx
MB256 plus from V03.xx
During commissioning, the BUS-2 address is to be set up after connecting the operating voltage for
the first time.
The BUS-2 address will be stored permanently even when disconnecting the operating voltage.
4.1 Required software versions:
4.2 Commissioning note
5. Planning information
40°
5.1 Angle of view
5.2 VdS-Kit
For installations according to
VdS regulations a VdS-Kit is available.
Mounting plate and sealing stickers for
installations and sealings according to VdS.
Item no. 012578
VdS-Kit for TouchCenter
Take the angle of the display into consideration
when determining the mounting height.
Recommended installation angle/angle of view: