Honeywell Home W8150 Manual Download Page 11

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL

11

68-0282—11

Fig. 5. Wiring heat pump with emergency heat.

Fig. 6.  Wiring with a PC8900.

Fig. 7. Using a remote switch or timer.

Fig. 8. Wiring to an HRV/ERV.

Fig. 9. Wiring an exhaust fan.

Wake

Room

System

Fan

Heat

Auto

AM

DST

Tue

Y

C

R

W2 E

G O

Y

1

W

1

C

R

W

2

E

G O/B

M19998B

G

F

R

C

C

C

C

H

W

G

T

HVAC

W8150A

M35714A

W8900

REMOTE

AUX

DAMPER

C

R

XFMR

RH
RC

HUM
HUM

VNT
VNT

®

AT120

W8150A

EARD6TZ

NOTE:

CONFIGURE PC8900 SO ALL VENT PROGRAM

SETTINGS ARE OFF; THE VENT BUTTON ON THE 

PC8900 THEN SERVES AS A REMOTE AND THE W8150

CONTROLS BACKGROUND VENTILATION.

Ventilation Control

Ventilation Control

Service

Auto

Continuous

Off

 (Remote Only)              

M35715A

EARD6TZ

FAN TIMER

REMOTE

AUX

DAMPER

C

R

XFMR

AT120

W8150A

Ventilation Control

Ventilation Control

Service

Auto

Continuous

Off

 (Remote Only)              

M22001B

ERV/HRV

EARD DAMPER NOT USED WITH HRV/ERV.

REMOTE

AUX

DAMPER

C

R

XFMR

RED

BLACK

AT120

W8150A

1

1

FAN TIMER

NOTES:

– BALANCE THE HRV/ERV TO 160 CFM OR LOWER.

– SET VENTILATOR SPEED KNOB TO 0.

Ventilation Control

Ventilation Control

Service

Auto

Continuous

Off

 (Remote Only)              

M35716A

EXHAUST FAN

120 VAC

AT120

AT120

R8222

W8150A

REMOTE

AUX

DAMPER

C

R

BLUE

BLUE

RED

BLACK

XFMR

EARD6TZ

FAN TIMER

120

VAC

L1

L2

Summary of Contents for W8150

Page 1: ...HRAE 62 2 2010 standard Ventilation and Acceptable Indoor Air Quality in Low Rise Residential Buildings Microcontroller optimizes the air delivery schedule to make efficient use of normal HVAC run times Easy to use input dials allow customized ventilation for each installation Test mode that includes immediate feedback to installer to confirm that air delivery requirements of selected ventilation ...

Page 2: ... Vac 12 VA 60 Hz Operation Power open spring closed Diameter 6 in Transformer AT120 Input 120 Vac Output 27 Vac open circuit 24 Vac full load at 20 VA Mounting Foot mounted Temperature 20 F to 160 F 29 C to 71 C Humidity 5 to 90 RH noncondensing Input Setting Ranges Bedrooms 2 5 Area 1000 4600 sq ft Vent Airflow 40 160 cfm Composite Setting Resolution 12 of ASHRAE 62 2 2010 recommended ventilation...

Page 3: ...ntilation continuously Off Remote Only W8150 supplies ventilation only when there is a remote call 8 Light Green Indicates device is powered and operating normally Used in Test Mode to signal if dial settings meet chosen standard 9 Light Red Indicates the device is not operating normally Used in Test Mode to signal if dial settings do not meet chosen standard 10 DIP1 Ventilation limit Choose betwe...

Page 4: ... or HRV ERV with a call for ventilation 18 DAMPER Damper two terminals 24 Vac powered contacts control fresh air damper 19 XFMR C 24 Vac ventilation control common Supplies power to W8150 and damper from transformer provided 20 XFMR R 24 Vac ventilation control power Supplies power to W8150 and damper from transformer provided No Name Description Function Device Number Component Location 1 Fresh a...

Page 5: ... To prevent complete opening move the red tab to the desired range stop location Wiring the control CAUTION Electrical Hazard Can cause personal injury or equipment damage Disconnect power to all systems before beginning installation 1 Wire the control See wiring diagrams in Fig 1 10 as listed below All wiring must comply with local codes ordinances and regulations 2 Reapply power to system and co...

Page 6: ... the control to meet the ventilation requirements for the home Ventilation Standard Building codes are different everywhere The W8150 Ventilation Control can be configured to operate based on ASHRAE 62 2 ASHRAE 62 1999 TIP Clear understanding of local codes and practices is required to make sure the ventilation system is installed and configured correctly Generally ASHRAE 62 2 control method is re...

Page 7: ...l to the nearest value For airflow set airflow cfm dial to the nearest value Vaulted ceilings do not need to be considered when setting this control For homes with multiple systems Resideo recommends a ventilation control and fresh air intake for each system Measure ventilation airflow for each system independently Refer to Multi system Setup Example for further details Customizing the ventilation...

Page 8: ...oblem Not enough airflow Ventilationon timelimit setting If the device is set to 60 Set the ventilation control to 100 maximum on time This allows the HVAC fan to run up to 100 of the time It may be preferable to increase airflow If the device is set to 100 There is not enough airflow through the fresh air duct Ventilation continues to occur according to the settings but chosen standard may not be...

Page 9: ... to actuator Damper actuator motor failure or mechanical failure Manually open damper and verify free movement damper should return to closed position when no power is applied If damper moves freely but does not operate when 24 volts is applied replace damper actuator If damper does not move freely replace fresh air damper Cooling compressor comes on when there is no cooling call from the thermost...

Page 10: ...p without emergency heat Wake Room System Fan Heat Auto AM DST Tue R C W Y G R RC W Y G M19994C GF RC CC CH W GT W8150A HVAC Wake Room System Fan Heat Auto AM DST Tue W R HVAC COOLING HEATING R C C Y G R RC W Y G M19995C GF RC CC CH W GT NOTE REMOVE FACTORY INSTALLED JUMPER BETWEEN CC AND CH ON W8150 W8150A Wake Room System Fan Heat Auto AM DST Tue W1 C R W2 Y1 Y2 G W1 C RC R W2 Y1 Y2 G M19996B GF...

Page 11: ...TTON ON THE PC8900 THEN SERVES AS A REMOTE AND THE W8150 CONTROLS BACKGROUND VENTILATION Ventilation Control Ventilation Control Service Auto Continuous Off Remote Only M35715A EARD6TZ FAN TIMER REMOTE AUX DAMPER C R XFMR AT120 W8150A Ventilation Control Ventilation Control Service Auto Continuous Off Remote Only M22001B ERV HRV EARD DAMPER NOT USED WITH HRV ERV REMOTE AUX DAMPER C R XFMR RED BLAC...

Page 12: ...ms fresh air intake measured at 127 cfm System 2 serves 1800 sq ft four bedrooms fresh air intake measured at 98 cfm Set W8150 for System 1 3100 sq ft four bedrooms 130 cfm Set W8150 for System 2 1900 sq ft two bedrooms 100 cfm CONVERSION TABLE Wake Room System Fan Heat Auto AM DST Tue W1 C R W2 Y1 Y2 G W1 C RC R W2 Y1 Y2 G M22021C GF RC CC CH W GT HVAC W8150A HUMIDIFIER FAN R8222 BLACK BLUE BLUE ...

Reviews: