Typical Mounting Locations
We recommend the UV Air Purifier be installed on the supply side duct 3–5 inches
above the A-coil, but it can also be installed on the return side if necessary. See
Figures 1 and 2.
The germicidal UV light should be positioned to shine on the surfaces that are prone
to mold growth like the A-coil, or be placed in an open area of the return duct where
there are long straight runs.
WARNING:
Do not mount device in location that allows ultraviolet light to be seen
after installation other than by the UV protected lamp handle or sight glass.
Important:
Some materials inside the HVAC system (including filter media, flex duct,
wiring etc.) may not be UV light resistant. Cover materials affected by UV light with UV
shielding or reflective tape.
The AirBRIGHT™ Odor Absorber unit should be oriented so that the air flows past the
UV Light first then into the AirBRIGHT Odor Absorber.