Fig. 10. T8775 Thermostat (features and operation).

SYSTEM Switch

Heat: The thermostat controls the heating system.
Off:

Both heating and cooling systems are off.

Cool: The thermostat 

controls the cooling system.

FAN Switch

Auto: 

The fan only runs with the heating and 
cooling system.

On: 

The fan runs continuously. Use for 
improved air circulation.

CHECKOUT

NOTE:

Temperature setpoint range is 40°F to 
90°F (4°C to 32°C) in heating and 45°F to 
99°F (7°C to 37°C) in cooling.

Heating

1.

Slide the SYSTEM switch to Heat and the 
FAN switch to Auto (T8775C only).

2.

Raise the temperature setpoint several 
degrees above the room temperature.

3.

A flame 

 will appear in the display and the 

heat should turn on.

4.

Lower the temperature setpoint below the 
room temperature.

5.

The flame   will disappear from the display 
and the heat should turn off.

Cooling (T8775C only)

CAUTION

Low Temperature Hazard.
Operating at too low of an outdoor 
temperature may cause compressor 
damage.

Do not operate cooling if outdoor 
temperature is below 50°F (10°C). Refer to 
manufacturer’s recommendations. 

NOTE:

If a call for cooling is made before the 
compressor has been off for five minutes, 
or if a power interruption occurs while the 
compressor is running, the thermostat 
will go into a five-minute delay to protect 
the compressor. The snowflake 

 will 

flash during this delay.

1.

Slide the SYSTEM switch to Cool and the 
FAN switch to Auto.

2.

Lower the temperature setpoint several 
degrees below the room temperature. 

3.

After approximately five minutes, the ther-
mostat will display a solid snowflake 

 and 

the cooling should turn on.

4.

Raise the temperature setpoint above the 
room temperature.

5.

The snowflake 

 will disappear from the dis-

play and the cooling should turn off. 

Fan

1.

Slide the SYSTEM switch to Off and the FAN 
switch to On. The fan should run continuously.

2.

Slide the FAN switch to Auto. The fan 
should turn off.

ROOM

SET

DISPLAYS ROOM 
OR SET TEMPERATURE

M19520

SHOWS THAT THE
CURRENT TEMPERATURE
SETPOINT IS DISPLAYED.

(T8775C ONLY)
SELECTS
ON/AUTO

(T8775C ONLY)
SELECTS 
COOL/OFF/HEAT

DISPLAYS AND ADJUSTS 
TEMPERATURE SETPOINT/TURNS
BACKLIGHT ON

SHOWS THAT THE
CURRENT ROOM 
TEMPERATURE IS
DISPLAYED.

Summary of Contents for The Digital Round T8775A

Page 1: ...uct to make sure the prod uct is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power supply before installation Location Install the thermostat ab...

Page 2: ...HEATING RELAY OR VALVE COIL M19513 1 1 M19514 HEATING RELAY OR VALVE COIL FAN RELAY 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 2 FACTORY INSTALLED JUMPER 1 2 W R Rc B O Y G 1 HEATING RELAY OR VALVE COIL COMPRESSOR CONTACTOR FAN RELAY M19515 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 2 FACTORY INSTALLED JUMPER 2 W R Rc B O Y G 1 2 1 ...

Page 3: ...Heat Cycle Rate Fahrenheit Celsius Indication Use DIP switch 3 to set the desired temperature indication See Table 2 Table 2 Temperature Indication Mounting Thermostat to Wallplate Fig 9 Mounting thermostat to wallplate OPERATION Setting SYSTEM and FAN Switches T8775C only System and fan settings are controlled manually by using the switches located at the top of the thermostat See Fig 10 M19497 F...

Page 4: ...n on 4 Lower the temperature setpoint below the room temperature 5 The flame will disappear from the display and the heat should turn off Cooling T8775C only CAUTION Low Temperature Hazard Operating at too low of an outdoor temperature may cause compressor damage Do not operate cooling if outdoor temperature is below 50 F 10 C Refer to manufacturer s recommendations NOTE If a call for cooling is m...

Page 5: ...uit pour s assurer que celui ci convient à l usage prévu 3 L installateur doit être un technicien d expérience ayant reçu une formation pertinente 4 Une fois l installation terminée vérifier le fonctionnement du produit en suivant les présentes instructions MISE EN GARDE Risque de choc électrique ou de dommages matériels Peut causer des blessures par choc électrique ou provoquer un court circuit C...

Page 6: ...nt avec un seul transformateur MF19499 CHEVILLES D ANCRAGE 2 TROU DE CÂBLAGE PLAQUE DE COMMUTATION VIS 1 PO 2 1 DANS LE CAS D UNE INSTALLATION AVEC CHEVILLES D ANCRAGE PERCER DES TROUS DE 3 16 PO SI LE MUR EST EN PLACOPLTRE OU DE 7 32 SI LE MUR EST EN PLTRE 1 ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES W R RELAIS DE CHAUFFAGE OU BOBINE DE VANNE M...

Page 7: ...e d énergie Microrupteurs Régler les cycles de chauffage ou l affichage de la température en degrés Celsius ou Fahrenheit à l aide des microrupteurs 1 2 3 au dos du thermostat Voir la Fig 8 Fig 8 Microrupteurs 1 2 1 RELAIS DE CHAUFFAGE OU BOBINE DE VANNE CONTACTEUR DU COMPRESSEUR RELAIS DE VENTILATEUR MF19517 1 ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SU...

Page 8: ... Système de chauffage Cycles par heure Micro rupteur 1 Micro rupteur 2 Vapeur gravité 1 On On Air chaud haute efficacité efficacité 90 eau chaude pompe à chaleur 3 Off On Air chaud au gaz ou mazout réglage en usine 6 Off Off Air chaud électrique 9 On Off Chaleur rayonnante dans les planchers Vérifier les cycles recommandés auprès du fabricant Affichage en Celsius ou Fahrenheit Microrupteur 3 Fahre...

Page 9: ... basses températures Le fonctionnement du système de refroidissement lorsque la température extérieure est trop basse peut endommager le compresseur Ne pas faire fonctionner le système en mode refroidissement si la température extérieure est inférieure à 10 C 50 F Lire les recommandations du fabricant REMARQUE Si un appel de refroidissement est effectué moins de cinq minutes après l arrêt du compr...

Page 10: ...T8775A C THE DIGITAL ROUND 69 1677EF 03 6 ...

Page 11: ...T8775A C THE DIGITAL ROUND 7 69 1677EF 03 ...

Page 12: ...ideoTechnologies Inc and its affiliates Tous droits réservés La marque de commerce Honeywell Home est utilisée avec l autorisation d Honeywell International Inc Ce produit est fabriqué par Resideo Technologies Inc et ses sociétés affiliées www resideo com Resideo Technologies Inc 1985 Douglas Drive North Golden Valley MN 55422 1 800 468 1502 69 1677EF 03 M S Rev 03 20 Imprimé aux États Unis ...

Reviews: