SPECIFICATIONS 

Range: 

0’- 25’/ 0 – 7.6m; Selectable

 

 

Battery

: 1 x 3V, Lithium; Resideo 466, Panasonic CR123A, Duracell DL 123, Duracell DL 123A 

Tamper

: Cover and Wall  

RF Frequency

: 2.4GHz

 

 

Operating Temperature

: 0° to 50° C / 32° to 122° F (Agency compliance 0° to 49° C   

   / 32° to 120° F)  

Relative Humidity

: 95% max. (Agency compliance – 93% max.), non-condensing  

Dimensions

: 96 mm Diameter x 29mm Thick / 3.78” Diameter x 1.14” Thick

 

APPROVAL LISTINGS 

FCC / IC 

cETLus Listed  

  Conforms to UL 639 

  Certified to ULC-S306 

Other Standards: 

RoHS

 

 

Protected Glass Types Chart 

NOTE: 

The PROSiXGB is NOT recommended for protection of glass areas smaller than 27.6 cm x 27.6 cm (10-7/8 inches x 10-7/8 inches). 

Glass Type* 

Nominal Thickness 

Minimum 

Maximum 

Plate

3a

 

2mm (3/32 in.)

 

10mm (3/8 in.) 

Tempered

 

3mm (1/8 in.)

 

10mm (3/8 in.) 

Laminated

1

 

4mm (5/32 in.)

 

14mm (9/16 in.) 

Wired

 

6mm (1/4 in.)

 

6mm (1/4 in.) 

Coated

2

 

3mm (1/8 in.)

 

6mm (1/4 in.) 

Sealed Insulating

3b

 

3mm (1/8 in.) [13mm (1/2 in.) overall] 

6mm (1/4 in.) [19mm (3/4 in.) overall] 

* Minimum size for all types is 28cm (11 in.) square; glass must be framed in the wall or mounted in a barrier at least 0.9m (36 in.) wide. 

Protected only if both plates in the unit are broken 

Coated glass with security films up to 0.35mm (14 mils) thick (including films for solar protection) may be used. Evaluated with the these products: 3M

®

 SCOTCHSHIELD

®

 

SH14CLARL – 0.35mm (14 mils), 4 ply film; Film Technologies International, Inc.’s GLASS-GARD GGLL 1200 has been evaluated with this product by Underwriters 

Laboratories, Inc. 

In compliance with Underwriters Laboratories of Canada’s Standard for Intrusion Detection Units (CAN/ULC-S306-M89): 

a. Plate glass 2.5mm (3/32 in.) to 10mm (3/8-in.) can be used. 

b. Seal Insulating glass 4mm (5/32 in.) [15mm (19/32 in.) overall] to 6mm (1/4 in.) [(19mm) 3/4 in. overall] can be used. Sensitivity should be set to High when protection 

range is greater than 3.8m (12.5 ft). 

FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS 

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could 

void the user's authority to operate the equipment. 

CLASS B DIGITAL DEVICE STATEMENT 

This equipment has been tested and found to comply with the limits for a Class B digital device, as defined by FCC Rules Part 15.105. The Class B Digital Device statement can be 

viewed at: 

https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx 

FCC / IC STATEMENT 

This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne 

doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. 

 

RF EXPOSURE 

Warning 

– The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating 

in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. 

Mise en Garde 

Exposition aux Frequences Radio: 

L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins  

7,8 pouces (20 cm) de toutes les personnes. 

 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE 

ALARM SYSTEM. 

 

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center Drive., 

Melville, NY 11747, Ph: 516-577-2000

 

 

The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The 

correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health. 
Any attempt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly prohibited. 

 

SUPPORT & WARRANTY INFORMATION 

For the latest documentation and support, please go to: 

www.resideo.com  

 

For the latest warranty information, please go to: 

www.security.honeywellhome.com/warranty  

The Honeywell Home Trademark is used under license from Honeywell International Inc. 

This product is manufactured by Resideo

 

Technologies, Inc.

 

and its affiliates. 

 

  

 

  

   

Ê800-Š 

800-25231B   2/19   Rev B

 

2 Corporate Center Drive, Suite 100 

P.O. Box 9040, Melville, NY 11747 

© 

2020

 

Resideo Technologies, Inc. 

www.resideo.com   

 

Summary of Contents for PROSiX Series

Page 1: ... and any heavy window coverings when heavy window coverings are present the detector can be mounted on the window frame Avoid mounting the detector on the same wall as the protected glass on free standing posts or pillars or in rooms with noisy equipment air compressors bells power tools etc if this equipment is operated when the detector is armed To remove the mounting bracket Turn the top of the...

Page 2: ...rs down Activate the tamper power down and up again or use the FG 701 Glassbreak Simulator to restart the enrollment process 1Refer to the PROSiXGB LEDs section NOTE Once enrolled in a system the detector cannot be used with another controller until it is removed from the current controller See the Controller s instructions for details PROGRAM THE PROSIXGB Consult the Controller s instructions for...

Page 3: ...d diagnosis To save power the LEDs are not visible during Normal Mode TEST THE PROSIXGB The detector should be tested after installation and at least once a year Test Mode can be activated remotely from the Controller see Controller s manual or on site with an FG 701 Glassbreak Simulator only when the system is disarmed Follow directions in the FG 701 Glassbreak Simulator Operating Instructions to...

Page 4: ...viewed at https customer resideo com en US support residential codes and standards FCC15105 Pages default aspx FCC IC STATEMENT This device complies with Part 15 of the FCC Rules and Industry Canada s license exempt RSSs Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferenc...