© The Smart Thermostat Shop 2021
User Interface Guide – Troubleshooting
Binding the device
Once batteries are
inserted the TRV
confirms this
by
flashing both LEDs
green for 5 secs
If inserted
batteries are low,
LED permanently
Amber (5 secs)
Press binding
button for 5
seconds
Right LED will
flash amber for up
to 2 minutes
whilst
binding
Succesful binding
is confirmed by
right LED showing
permanently green
for 5 seconds
After 2 minutes
binding timesout
(if unsuccessful)
TRV will return to
normal default
mode
Short press
binding button
Green flash (5
secs)
indicates no
issue
Permament amber
(5 secs)
indicates
the battery is low
Permanent amber
(3 secs)
Batteries
are critical, less
than 2.1V. Buttons
function locked
Permanent red (10
secs)
indicates a
mounting issue
Red flash (10
secs)
indicates a
signal issue
(signal lost or not