background image

 

30 

Accessing Other Partitions (Vista-20P) 

About Accessing Partitions (VISTA-20P) 

(GOTO Command and Multi-Partition Arming) 

Each keypad is assigned a default partition for display purposes, and will show only that partition's 

information.  

 

  If the user is authorized, a keypad in one partition can be used to perform system functions in the 

other partition by using the 

GOTO 

command. Refer to the GOTO section. 

 

  If the user is authorized, that user can arm other partitions. Refer to the Multi-Partition Arming 

section.  

The following table shows the relationship of the keypads in each partition when system is armed and 

disarmed.  

 

 

 

PARTITION 1

 

PARTITION 2

 

COMMON ZONE 

(LOBBY, etc.)

 

Arming 

State 

Keypad 

Status 

Arming 

 

State 

Keypad  

Status 

Arming 

State 

Keypad  

Status 

Condition 1 

 

Disarmed 

Partition 1  

Only

 

Disarmed 

Partition 2  

Only

 

Disarmed  Common Zone 

Only

 

Condition 2 

 

Disarmed 

Partition 1 and 

Common Zone 

Armed 

Partition 2  

Only

 

Disarmed  Common Zone 

Only

 

Condition 3 

 

Armed 

Partition 1   

Only

 

Disarmed  Partition 2 and 

Common Zone 

Disarmed  Common Zone 

Only

 

Condition 4 

 

Armed 

Partition 1  

Only

 

Armed 

Partition 2  

Only

 

Armed 

Common Zone 

Only

 

 

When both partitions are disarmed, the keypad in each partition displays zone status for its partition 

only. The common zone keypad shows the status in that zone only. See Condition 1 above. 
When partition 1 is disarmed and partition 2 is armed, the keypad in partition 1 shows the status of 

partition 1 

and

 the common zone. Partition 2 will display the status of partition 2 

only. 

See

 

Condition 2 

above. 
When partition 1 is armed and partition 2 is disarmed, the keypad in partition 1 shows the status of 

partition 1

 only

. Partition 2 will display the status of partition 2 

and

 the common zone

See

 

Condition 3 

above. 

As long as any one of the two partitions is disarmed, the common zone will always be disarmed. 

The common zone will be armed only when both partition 1 and 2 are armed. See Condition 4 

above. 

Summary of Contents for Ademco Vista Series

Page 1: ...ADEMCO VISTA SERIES VISTA 15P VISTA 15PSIA VISTA 20P VISTA 20PSIA User Guide K5309 1V7C 3 15 Rev C VISTA 15P 15PSIA VISTA 20P 20PSIA...

Page 2: ...signed for use with devices manufactured or approved by Resideo Technologies Inc through its subsidiary Ademco Inc Resideo for use with your security system Your security system is not designed for us...

Page 3: ...Arms Perimeter Only Entry Delay Off 13 AWAY Mode Arms Entire System Entry Delay On 13 MAXIMUM Mode Arms Entire System Entry Delay Off 13 Arming Commands 14 Single Button Arming 15 Single Button Step A...

Page 4: ...ition Arming VISTA 20P 31 Common Zone Operation VISTA 20P 32 Scheduling 33 About Scheduling 33 Creating Schedules 33 Event Logging Procedures 35 About Event Logging 35 Viewing the Event Log 35 Underst...

Page 5: ...ight Stay Away Instant Maximum STAY arms perimeter zones only and entry delay is on INSTANT same as STAY except entry delay is off NIGHT STAY arms perimeter zones and selected interior zones entry del...

Page 6: ...ame partition Arming Step Arming and Disarming Burglary Protection The system must be armed before the burglary protection can sense intrusions To arm your system enter your security code followed by...

Page 7: ...sage Center if Voice Keypad is installed Voice keypads feature a voice message center that lets you record and playback one message The message can be up to 2 5 minutes long The message remains in mem...

Page 8: ...dicates that an alarm has occurred during your absence and an intruder may still be on the premises LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location Your keypads are functionally t...

Page 9: ...e wireless key fobs which can perform various functions programmed by your installer IMPORTANT SECURITY NOTICE Your key fob is similar to your keys or access card If lost or stolen another person can...

Page 10: ...battery power AC Appears when AC power is present CHIME Appears when the chime feature is activated BAT Low battery condition in a wireless sensor if zone number displayed or low system battery if no...

Page 11: ...l key depressions must be made within 4 5 seconds of one another If 4 5 seconds elapse without a key depression the entry will be aborted and must be repeated from its beginning Be sure to observe thi...

Page 12: ...eter portion of burglary system only Interior protection is not armed allowing movement within premises without causing an alarm If pressed twice in succession arms system in Night Stay mode PLAY On V...

Page 13: ...stem functions 15 MIC On voice keypads microphone for Message Center recordings 16 MESSAGE LED INDICATOR RED On Voice keypads flashes red when message waiting or lights red steady when in record mode...

Page 14: ...n 2 on VISTA 20P Series only ____________________________________________ Exit Delay seconds Entry Delay 1 seconds Entry Delay 2 seconds Exit Delay Exit delay gives you time to leave through the desig...

Page 15: ...minimize false alarms sent to the Central Monitoring Station Ask your installer if Exit Alarm is active in your system If so check this box VISTA 20PSIA VISTA 15PSIA The Exit Error condition works th...

Page 16: ...ghts when all protection zones have been either closed or bypassed 3 Arm the system as desired Alpha Display DISARMED HIT FOR FAULTS Fixed Word Display Zone no and NOT READY Voice Status Voice keypads...

Page 17: ...s are armed and cause an alarm if anyone enters those areas e g waking in the middle of the night To avoid sounding an alarm you must disarm the system before any activity takes place in those interio...

Page 18: ...security code 4 MAX same as AWAY described above Note that entry delay is turned off Arming Ding In addition to the keypad beeps the external sounder emits a short ding sound after arming if programm...

Page 19: ...all perimeter doors and windows 1 Press and hold the assigned function key for 2 seconds no code is required Function keys are shown below Alpha Display DISARMED READY TO ARM Fixed Word Display Green...

Page 20: ...ee your installer for the meanings of the lit red light Lit Steady system armed AWAY or system armed STAY and exit delay has expired Flashing system armed STAY and exit delay timer active Rapid flashi...

Page 21: ...ry delay has started you ve opened the entry door you do not need to press the OFF key simply enter your security code The system will disarm in about 15 seconds after the last digit of the code is en...

Page 22: ...ated The system will not allow fire zones to be bypassed Zones are automatically unbypassed when the system is disarmed 1 6 BYPASS zone number see below Security Code Enter the 2 digit zone number for...

Page 23: ...a few moments all open zones will be displayed and automatically bypassed Make sure that only those zones that you wish to leave unprotected are bypassed and that there are no other zones unintentiona...

Page 24: ...ity Code The CHIME message will appear Alpha Display DISARMED CHIME READY TO ARM Fixed Word Display CHIME To turn Chime Mode off 9 CHIME Security Code The CHIME message will disappear Alpha Display DI...

Page 25: ...check mark in the box beneath that key Setting the Date and Time NOTE All partitions must be disarmed before date time can be set You can set the time and date by doing the following 1 6 3 Master Code...

Page 26: ...rens Fire Alarm fire alarm temporal pulsing sound at external bells and sirens All panic functions send signals to the Central Monitoring Station if connected To activate a Panic Function Press and ho...

Page 27: ...macros can be assigned See the chart at the back of this manual for the key s assigned for macros 1 6 6 Master Code Alpha Display DISARMED READY TO ARM 2 Enter the macro number 1 4 for VISTA 20P Seri...

Page 28: ...Macro Alpha Display MACRO PGM 602F603F 701F2F Function Keystrokes Required Keypad Display 1 Bypass zones 02 03 Press BYPASS 6 key then 2 digit zone number 02 then terminator D then 6 then 2 digit zone...

Page 29: ...e manually turned on or off using the commands described below See your installer for a list of devices that may be set up for your system A list of these devices is provided at the back of this manua...

Page 30: ...t to the pager The pager display format is as follows Optional 16 digits 3 digit Event Code AAAAAAAAAAAAAAAA BBB CCCC 1 digit Partition No 3 digit Zone No or User No A B C Optional 16 digits for Accou...

Page 31: ...for beep then press the pager number 1 4 representing the pager intended to receive the message 2 The recipient on seeing the 999 9999 message will understand the prearranged meaning of this signal I...

Page 32: ...ost normal user situations Therefore the only step you usually need to do when adding users is assign a user number from the partition s pre assigned user numbers and a security code Authority Level D...

Page 33: ...en set an access schedule that defines the times this group of users can operate the system The system ignores these users outside the scheduled times User s Partition System Master Code 8 user no 3 0...

Page 34: ...Partition 1 and Common Zone Armed Partition 2 Only Disarmed Common Zone Only Condition 3 Armed Partition 1 Only Disarmed Partition 2 and Common Zone Disarmed Common Zone Only Condition 4 Armed Partiti...

Page 35: ...ctive partition number is displayed in the upper left portion of screen if the option is selected Alpha Display 2 DISARMED READY TO ARM Fixed Word Display Green LED lit Multi Partition Arming VISTA 20...

Page 36: ...s are armed If only one partition is armed the system ignores faults on the common zone Either partition may arm its system if the common zone is faulted but once armed the other partition will not be...

Page 37: ...for a list of output device numbers used in your system 02 set a user access schedule for one or more users see Security Codes section for an explanation of access groups 03 send a latch key report t...

Page 38: ...only to event numbers 01 02 and 03 Refer to step 7 for available entries Press to continue STOP SMTWTF S HH MMAM 1000000 9 Enter the desired repeat option 0 no repeat 1 repeat schedule weekly 2 repeat...

Page 39: ...fied by its corresponding code refer to the code table that follows zone or user number depending on type of event partition in which event occurred time and date of the event s occurrence 3 Pressing...

Page 40: ...RF Sensor Low battery 393 Clean Me Code Definition 401 R401 Armed AWAY MAXIMUM E401 Disarmed 403 Schedule Arm Disarm AWAY 406 Cancel by User 407 Remote Arm Disarm Downloading 408 Quick Arm AWAY 409 Ke...

Page 41: ...Open each protected door and window in turn and listen for three beeps from the keypad Identification zone number or zone description of each faulted protection point should appear on the display The...

Page 42: ...VICE Note A display of CHECK 70 on Alpha Display keypads indicates that the wiring connection to the external sounder is at fault opened or shorted and you should CALL FOR SERVICE See BELL FAILURE on...

Page 43: ...er or BAT with number displayed 00 is RF keypad zone No Accompanied by a single beep about once every 30 seconds at the keypad Either replace the battery yourself or CALL FOR SERVICE If the battery is...

Page 44: ...nd back up battery for the system has been interrupted and the system is inoperative CALL FOR SERVICE In The Event Of Telephone Operational Problems In the event of telephone operational problems disc...

Page 45: ...ansmitter and the portable wireless keypad and displays a low battery message A low battery in a portable wireless keypad is detected as soon as one of its keys is pressed and displayed as 00 Battery...

Page 46: ...pressing the OFF key the security code is not needed to silence fire alarms To clear the display enter your code and press the OFF key again to clear Memory of Alarm 2 If the Keypad s FIRE display doe...

Page 47: ...ned for FIRE Emergency A key or key pair may have been assigned for manually initiating a FIRE alarm See the Panic Keys section for key assignments For convenience indicate the key or key pair assigne...

Page 48: ...re detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke detector installed outside of each separate sleeping area in th...

Page 49: ...dows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that...

Page 50: ...ay or an alarm is active Also silences sounders Memory of alarm remains until cleared Clear Alarm Memory After disarming enter code again Press OFF 1 key again Keypad beeps rapidly on entry if alarm h...

Page 51: ...YSTEM WILL AUTOARM WITHIN 10 MINUTES a Opened zone numbers will appear b BAT displayed with zone number of transmitter c No special display TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM AWAY is disp...

Page 52: ...NUTES a Opened Zone identifications will appear b LO BAT displayed with description of transmitter c No special display TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM ARMED AWAY or MAXIMUM displayed...

Page 53: ...that it and the radio or television receiver are on different branch circuits Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA CLASS B STATEMENT This Class B digital a...

Page 54: ...normes de protection d exploitation et de s curit des r seaux de t l communications comme le prescrivent les documents concernant les exigences techniques relatives au mat riel terminal Le Minist re...

Page 55: ...e of LED lighting Arm AWAY steady flash Arm STAY steady flash Function Keys A B C D Comments Single Button Arming Step Arming Paging see Paging chart Time Date Display Macro Key 1 Macro Key 2 Macro Ke...

Page 56: ...t s system master only 3 part s Security Code enter new code Auth Level 1 level Access Group 2 group RF Zone Number 4 zone no Pager on off 5 0 1 01 installer all installer 1 02 system master all maste...

Page 57: ...1 46 2 0 1 47 2 0 1 48 2 0 1 49 2 0 1 Authority Levels 0 standard user Partitions 0 clears partition 1 and partition 2 defaults 1 arm only 1 partition 1 and common 2 guest 2 partition 2 and common 3...

Page 58: ...e on off 04 forced STAY arm 07 display reminder 02 user access 05 forced AWAY arm Repeat Options 0 none 1 repeat weekly 2 repeat every other week 3 repeat every third week 4 repeat every fourth week V...

Page 59: ...y No VISTA 20P VISTA 15P Other _______________________________________________ circle the appropriate model number Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B...

Page 60: ...Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All windows Interior locations All Accessible...

Page 61: ...our local authorized service representative is the person best qualified to service your alarm system Arranging some kind of regular service program with him is advisable Your local service representa...

Page 62: ...58 NOTES...

Page 63: ...prevent injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide vol...

Page 64: ...AGES Any product description whether in writing or made orally by Seller or Seller s agents specifications samples models bulletin drawings diagrams engineering sheets or similar materials used in con...

Reviews: