10
PREPARATION
4.
Connect the suction hose.
Always install the strainer on the end of the suction hose before
pumping. The strainer will exclude debris that can cause clogging or
impeller damage.
SUCTION HOSE
HOSE CONNECTOR
SUCTION PORT
HOSE CONNECTOR
HOSE BAND
HOSE BAND
HOSE COUPLING PACKING (commercially available)
HOSE COUPLING (commercially available)
SUCTION HOSE
(commercially available)
HOSE CLAMP RING
(commercially available)
STRAINER
SUCTION HOSE
HOSE BAND
1.
Use commercially available hose, hose connector, and hose bands.
The suction hose must be of reinforced, noncollapsible construction.
Suction hose length should not be longer than necessary, as pump
performance is best when the pump is not far above the water level.
Self-priming time is also proportional to hose length.
Tighten the hose connector and bands to prevent air leakage and loss
of suction. A loosely connected suction hose will reduce pump
performance and self-priming ability.
The strainer that is provided with the pump should be attached to the
end of the suction hose with a band, as shown.
Type C
X
X
X
Type
UD,
DE
EQUIPMENT PARTS
HOSE CLAMP RING
HOSE COUPLING
HOSE COUPLING PACKING
HOSE BAND
STRAINER
Type C
Type UD, DE
Summary of Contents for WT20X
Page 9: ... 6 C and UD types WT30X WT40X WT20X French labels come with the water pump ...
Page 48: ...MANUEL DE L UTILISATEUR Honda WT20X WT30X WT40X Notice originale ...
Page 55: ... La pompe à eau comporte des étiquettes en français Types C et UD WT20X WT30X WT40X 6 ...
Page 94: ...BEDIENUNGSANLEITUNG Honda WT20X WT30X WT40X Originalbetriebsanleitung ...
Page 140: ...MANUAL DE EXPLICACIONES Honda WT20X WT30X WT40X Manual original ...
Page 147: ... La bomba de agua se sirve con etiquetas en francés español WT30X WT40X WT20X Tipos C y UD 6 ...