DOCKING STATION
TRANSFORMER INSPECTION
Check for continuity between the terminals of
transformer plug [1].
Check for continuity between the terminals of
transformer 2P connector [2].
Measure the resistance between the terminals of
transformer plug [1].
Measure the resistance between the terminals of
transformer 2P connector [2].
Terminal
Type
Resistance (
Ω
)
(at 20 °C/68 °F)
Plug [1]
EAE/EAS
27 - 56
EAB
32 - 63
Terminal
Resistance (
Ω
)
(at 20 °C/68 °F)
2P connector [2]
0.6 - 1.8
EAE type shown:
[2]
[1]
EAE type
EAS type
EAB type
[1]
[2]