Output and Overload Indicators
OUTPUT INDICATOR LIGHT
(GREEN)
OVERLOAD INDICATOR LIGHT
(RED)
The Output indicator (green) will remain ON during normal operating
conditions.
Stop the engine if the Overload indicator (red) comes ON and
investigate the overload source.
The Overload indicator (red) also lights in the following cases:
When the inverter is overheated; the current to the connected
appliance will be shut off. Check to see if the air intake is obstructed.
When an electric motor is started, both the Overload indicator (red)
and the Output indicator (green) may go on simultaneously. This is
normal if the Overload indicator (red) goes off after about five (5)
seconds. If the Overload indicator (red) stays on, consult your Honda
generator dealer.
Before connecting an appliance to the generator, check that it is in
good order, and that its electrical rating does not exceed that of the
generator. Then connect the power cord of the appliance, and start
the engine.
If the generator is overloaded (see page
), or if there is a short in the
connected appliance, the Output indicator (green) will go OFF, the
overload indicator (red) will go ON and current to the connected
appliance will be shut off.
29
08/10/21 20:24:20 32ZT7702_034
Summary of Contents for EU30is
Page 2: ...08 10 21 20 20 05 32ZT7702_002 ...
Page 12: ...10 U type 08 10 21 20 21 34 32ZT7702_012 ...
Page 65: ...63 EU26i G GW B F 08 10 21 20 29 46 32ZT7702_065 ...
Page 66: ...64 EU30is G GW B F 09 03 04 12 28 14 32ZT7702_066 ...
Page 67: ...65 EU30is U 09 03 04 12 28 20 32ZT7702_067 ...
Page 68: ...66 RECEPTACLE Shape Type B F U G GW 08 10 21 20 30 14 32ZT7702_068 ...