22
OPERATION
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 1 meter away
from building walls and other equipment during operation. Do not place
flammable objects close to the engine.
Operating this generator less than 1 meter from a building or other
obstruction can cause overheating and damage the generator. For
proper cooling, allow at least 1 meter of empty space above and
around the generator.
Refer to
SAFE OPERATING PRECAUTIONS
on page 21 and perform the
IS YOUR GENERATOR READY TO GO?
checks (see page 19). Refer to
AC OPERATION
(see page 25) for connecting loads to the generator.
1.Make sure that all appliances
are disconnected from the AC
receptacle.
2.Make sure that the AC circuit
breaker is in the OFF position.
3.Turn the fuel valve lever to the
ON position.
AC CIRCUIT BREAKER
OFF
FUEL VALVE LEVER
ON