OPERATION
STANDBY POWER
System Ground
Connections to a Building’s Electrical System
Honda portable generators have a system ground that connects the
generator frame components to the ground terminals in the AC output
receptacles. The system ground is not connected to the AC neutral
wire. If the generator is tested with a receptacle tester, it will not show
the same ground circuit condition as for a home receptacle.
In some areas, generators are required by law to be registered with
local utility companies. Check local regulations for proper registration
and use procedures.
Improper connections to a building’s
electrical system can allow current
from the generator to backfeed into
the utility lines.
Such backfeed may electrocute
utility company workers or others
who contact the lines during a
power outage, and the generator
may explode, burn, or cause fires
when utility power is restored.
Consult the utility company or a
qualified electrician prior to making
any power connections.
Your generator can supply power to a building’s electrical system. If
the generator will be used as an alternative to utility company power,
an isolation switch must be installed to disconnect the utility lines
from the building when the generator is connected. Installation must
be performed by a qualified electrician and must comply with all
applicable laws and electrical codes.
11/03/27 07:58:05 31Z11710_040
Summary of Contents for EM5000is
Page 1: ......
Page 79: ...77 TECHNICAL CONSUMER INFORMATION Wiring Diagram 11 03 27 08 04 03 31Z11710_078 ...
Page 100: ...98 MEMO 11 03 27 08 06 56 31Z11710_099 ...
Page 101: ...99 MEMO 11 03 27 08 06 58 31Z11710_100 ...
Page 102: ...100 MEMO 11 03 27 08 07 01 31Z11710_101 ...
Page 104: ...00X31Z117200 ...