Draining the Fuel Tank
1. Place a suitable container below the sediment cup.
2. Turn the fuel valve lever to the OFF position.
3. Remove the sediment cup (
), and then turn the fuel valve
lever to the ON position to drain the fuel from the fuel tank.
4. Install the sediment cup and a new O-ring.
5. Turn the fuel valve lever to the OFF position.
Cleaning
Wipe the generator with a moist cloth. After the generator has dried,
touch up any damaged paint, and coat other areas that may rust with
a light film of oil.
Oil
). Add oil in the engine cylinder to
prevent corrosion.
1. Remove the spark plug (
2. Pour a teaspoon (5 cc)
of clean engine oil into
the cylinder to keep it
from rusting.
3. Pull the starter rope
several times to
distribute the oil in the
cylinder.
4. Reinstall the spark
plug.
5. Pull the starter rope
slowly until resistance
is felt, and then return the starter grip gently. This will close the
valves so moisture cannot enter the engine cylinder.
Storage Location
If your generator will be stored with gasoline in the fuel tank and
carburetor, it is important to reduce the hazard of gasoline vapor
ignition. Select a well-ventilated dry storage area away from any
appliance that operates with a flame, such as a furnace, water heater,
or clothes dryer. Also avoid any area with a spark-producing electric
motor, or where power tools are operated.
Make sure the fuel valve is in the OFF position to reduce the
possibility of fuel leakage.
Place the generator on a level surface. Tilting can cause fuel or oil
leakage.
With the engine and exhaust system cool, cover the generator to keep
out dust. A hot engine and exhaust system can ignite or melt some
materials. Do not use sheet plastic as a dust cover. A nonporous
cover will trap moisture around the generator, promoting rust and
corrosion.
Removing from Storage
Check your generator as described in “BEFORE EACH USE” on
.
If the engine cylinder was coated with oil during storage preparation,
the engine may smoke briefly at startup.
TROUBLESHOOTING
Engine Will Not Start
Loss of Power
No Power at the AC Receptacles
OIL
SPARK PLUG
Possible Cause
Correction
Fuel valve lever OFF
Turn the fuel valve level ON
(
Out of fuel
Refuel (
).
Bad fuel; generator stored without
treating gasoline, or refueled with
bad gasoline
Refuel with fresh gasoline
(
).
Low oil level caused Oil Alert to
stop engine
Check oil level (
). Add
oil as necessary. Turn the
engine switch OFF and then
ON and restart the engine.
Spark plug faulty, fouled, or
improperly gapped
Gap or replace the spark plug
(
).
Spark plug wet with fuel (flooded
engine)
Dry and reinstall the spark
plug.
Fuel filter clogged, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
Take the generator to an
authorized Honda servicing
dealer for repair.
Possible Cause
Correction
Air filter is clogged
Clean or replace the air filter
(
).
Bad fuel; generator stored without
treating gasoline, or refueled with
bad gasoline
Refuel with fresh gasoline
(
).
Fuel filter clogged, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
Take the generator to an
authorized Honda servicing
dealer for repair.
Possible Cause
Correction
Output indicator is OFF, and the
overload alarm is ON
Check the AC load. Stop and
restart the engine. (
).
Check the cooling air inlet.
Stop and restart the engine.
AC circuit protector is tripped
Check the AC load and reset
the circuit protector. (
).
Faulty power tool or appliance
Replace or repair the power
tool or appliance. Stop and
restart the engine.
Faulty generator
Take the generator to an
authorized Honda servicing
dealer, or refer to the shop
manual. (
).