Honda EG2800i Owner'S Manual Download Page 18

18

AVOIDING FUEL-RELATED PROBLEMS

When properly maintained, your Honda generator should provide years of trouble-free operation. This includes the fuel system. However, 

gasoline can quickly deteriorate (in as little as 30 days) causing starting or running problems and, in some cases, damage to the fuel system. 

Most fuel-related problems can be avoided by following the precautions listed below. Fuel system damage and engine performance problems 

resulting from deteriorated gasoline are not covered by the 

DISTRIBUTOR’S LIMITED WARRANTY

 (

page 20

).

Follow These Precautions to Prevent Most Fuel-Related Problems

During the Normal Use

Reason

Do not use gasoline containing more than 10% ethanol (E10). Not 

all automotive gasoline is safe to use in your generator.

Higher levels of ethanol in gasoline attract water, and can corrode or 

damage the fuel system and cause performance problems. 

Store gasoline in a clean, plastic, sealed container approved for fuel 

storage. 

Store your fuel supply container away from direct sunlight; if the 

container has a vent, keep it closed.

A plastic container eliminates the risk of rust and metallic 

contaminants from a metal container entering the fuel system.

Gasoline will deteriorate faster when exposed to air and sunlight.

Purchase only enough gasoline to last for 1 to 2 months (about 30 to 

60 days).

If you purchase enough gasoline to last for more than 60 days, add 

a fuel stabilizer to your storage container when you fill it.

Gasoline deteriorates with age so try to avoid storing it for long 

periods, especially in summer heat.

Fuel stabilizer will extend the shelf life of gasoline, but it will not 

reconstitute stale fuel.

Keep your generator’s fuel tank full of fresh fuel when not in use. 

Turn the fuel valve OFF.

If the fuel tank is only partially filled, air in the tank will promote fuel 

deterioration.

Keep the air filter clean and properly serviced. Check it before each 

use.

A properly maintained air filter will help prevent dirt from entering the 

carburetor. The small passages inside the carburetor can become 

blocked.

3 to 4 Weeks Before Next Use

Reason

Keep your generator’s fuel tank full of fresh fuel when not in use. 

Turn the fuel valve OFF.

If the fuel tank is only partially filled, air in the tank will promote fuel 

deterioration.

Turn the fuel valve to the OFF position, start the engine and let it run 

approximately 3 minutes until the carburetor is empty and the 

engine stops. 

The small amount of gasoline in your engine’s carburetor will 

deteriorate faster than the fuel in the fuel tank due to its small 

volume and heat from the engine.

1 to 3 Months Before Next Use

Reason

If you did not add fuel stabilizer to your fuel storage container when 

you filled it up, fill your generator’s fuel tank with fresh gasoline. 

If the fuel tank is only partially filled, air in the tank will promote fuel 

deterioration.

Add fuel stabilizer to the generator’s fuel tank according to the 

stabilizer manufacturer’s instructions. 

Fuel stabilizer will extend the life of gasoline, but it will not 

reconstitute stale gasoline.

Run the engine outdoors for 10 minutes. 

This makes sure treated gasoline has replaced untreated gasoline 

throughout the fuel system.

Turn the fuel valve to the OFF position, start the engine, and let it 

run approximately 3 minutes until the carburetor is empty and the 

engine stops. 

The small amount of gasoline in your engine’s carburetor will 

deteriorate faster than the fuel in the fuel tank due to its small 

volume and heat from the engine.

More Than 3 Months Before Next Use

Reason

Remove the fuel from the carburetor and fuel tank (

page 13

.) Do not 

allow gasoline to remain in your generator’s fuel tank for more than 

3 months (about 90 days) of inactivity.

All fuel stabilizers have a shelf life. It is good practice to empty the 

fuel system for long term inactivity.

If you have fuel left in your storage container at the end of the operating season, recycle the fuel into your car’s fuel tank or dispose of it 

properly.

Summary of Contents for EG2800i

Page 1: ...Air Index 16 Controls 6 Air Cleaner 12 Specifications 16 Features 6 Spark Plug 12 Wiring Diagram 17 OPERATION 7 Sediment Cup Cleaning 13 AVOIDING FUEL RELATED PROBLEMS 18 Safe Operating Instructions 7...

Page 2: ...table power requirements Other uses can result in injury to the operator or damage to the generator and other property Most injuries or property damage can be prevented if you follow all the instructi...

Page 3: ...ignite some materials Keep the generator at least 3 feet 1 meter away from buildings and other equipment during operation Do not enclose the generator in any structure Keep flammable materials away f...

Page 4: ...ctane rating of 86 or higher containing no more than 10 ethanol E10 or 5 methanol by volume Refer to page 11 for additional fuel recommendations 1 Remove the fuel tank cap 2 Add fuel slowly to prevent...

Page 5: ...for signs of damage Check each control for proper operation Check that all nuts bolts and screws are tightened Check the air filter page 12 and oil level page 11 Check the fuel level page 7 Starting w...

Page 6: ...OFF position to reduce voltage changes ON Recommended to minimize fuel consumption and further reduce noise levels when less than a full load is applied to the generator OFF The Eco Throttle system d...

Page 7: ...ings and other equipment Do not operate the generator in an enclosed structure Do not place flammable objects close to the engine or locate the generator near flammable materials Starting the Engine T...

Page 8: ...wer cord can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately Disconnect the appliance and determine whet...

Page 9: ...able to your individual needs and use Remember that an authorized Honda servicing dealer knows your generator best and is fully equipped to maintain and repair it To ensure the best quality and reliab...

Page 10: ...able failures Item Action Before each use 5 hours of use or first month 25 hours of use or every 3 months 50 hours of use or every 6 months 100 hours of use or every year 250 hours of use or every 2 y...

Page 11: ...e DISTRIBUTOR S LIMITED WARRANTY If your equipment will be used on an infrequent or intermittent basis please refer to the fuel section of the STORAGE chapter page 13 for additional information regard...

Page 12: ...inside Never try to brush off dirt brushing will force dirt into the fibers 5 Foam Air Filter Wash the foam air filter in a solution of household detergent and warm water then rinse thoroughly or wash...

Page 13: ...el Position the generator so that its base is level on the bed of the transport vehicle Tie the generator down with rope or straps Keep the tie down rope or straps away from the controls Do not operat...

Page 14: ...cover A nonporous cover will trap moisture around the generator promoting rust and corrosion Removing from Storage Check your generator as described in BEFORE EACH USE on page 5 If the engine cylinder...

Page 15: ...ontrol systems to reduce the emissions of carbon monoxide oxides of nitrogen and hydrocarbons Additionally Honda fuel systems utilize components and control technologies to reduce evaporative emission...

Page 16: ...tended 300 hours 0 80 cc 500 hours greater than 80 cc 1000 hours 225 cc and greater EG2800i Lightweight inverter generator with Eco Throttle Length 16 9 in 430 mm Width 17 6 in 448 mm Overall height 1...

Page 17: ...17 Wiring Diagram...

Page 18: ...k it before each use A properly maintained air filter will help prevent dirt from entering the carburetor The small passages inside the carburetor can become blocked 3 to 4 Weeks Before Next Use Reaso...

Page 19: ...detailed description of the problem Honda Publications These publications will give you information for maintaining and repairing your generator Owner s Manual Keep this owner s manual handy so you c...

Page 20: ...w limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions and limitations may not apply to you...

Page 21: ...place other engine components damaged by a failure of any warranted part during the warranty period The use of replacement parts not equivalent to the original parts may impair the effectiveness of yo...

Page 22: ...22 NOTES...

Page 23: ...ne Complete and mail the postage paid card shown below Complete and submit the on line form at powerequipment honda com Scan the QR code below and then complete and submit the on line form commercial...

Page 24: ...ick Submit It s that simple Power Equipment Division American Honda Motor Co Inc 4900 Marconi Dr Alpharetta GA 30005 9956 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Product Registration BUSIN...

Reviews: