Honda EG2800i Owner'S Manual Download Page 8

8

7. If the choke rod was moved 

to the CLOSED position to 
start the engine, gradually 
push it to the OPEN position 
as the engine warms up.

8. If you wish to use the Eco 

Throttle system, turn the Eco 
Throttle system switch to the 
ON position after the engine 
has warmed up for 2 or 3 minutes.

Stopping the Engine

To stop the engine in an emergency, simply turn the engine switch to 
the OFF position. Under normal conditions, use the following 
procedure.
1. Turn off or disconnect all appliances that are connected to the 

generator.

2. Turn the engine switch to the 

OFF position.

3. Turn the fuel valve lever to 

the OFF position.

AC Operation

Before connecting an appliance(s) to the generator, make sure that it 
is in good working order and that the appliance(s) total electrical rating 
does not exceed that of the generator.
Most motorized appliances require more than their electrical rating for 
startup. When an electric motor is started, the overload alarm (red) 
may come on. This is normal if the overload alarm (red) goes off 
within nine seconds. If the overload alarm (red) stays on, consult your 
generator dealer.

NOTICE

Substantial overloading may damage the generator. Marginal 
overloading may shorten the service life of the generator.

1. Start the engine (

page 7

and make sure the output indicator 

(green) comes on.

2. Plug in the appliance.
3. Turn on the appliance.
If the generator is overloaded (in excess of 2.8 kVA), if there is a short 
circuit in a connected appliance, or if the inverter is overheated, the 
overload alarm (red) will come ON. The overload alarm (red) will stay 
ON, and after about 4~10 seconds, current to the connected 
appliance(s) will shut off, and the output indicator (green) will go OFF. 
Stop the engine and investigate the problem.
Determine if the cause is a short circuit in a connected appliance or an 
overload. Correct the problem and restart the generator.

AC Applications

Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. A faulty appliance or 

power cord can create a potential for electrical shock.

• If an appliance begins to operate abnormally, becomes sluggish, or 

stops suddenly, turn it off immediately. Disconnect the appliance, 
and determine whether the problem is the appliance or if the rated 
load capacity of the generator has been exceeded.

Most appliance motors require more than their rated wattage for 
startup.
Make sure the electrical rating of the tool or appliance does not 
exceed the maximum power rating of the generator.
Maximum power is: 2.8 kVA
For continuous operation, do not exceed the rated power. 
Rated power is: 2.5 kVA
In either case, the total power requirements (VA) of all appliances 
connected must be considered. Appliance and power tool 
manufacturers usually list rating information near the model number 
or serial number.

NOTICE

Substantial overloading that continuously lights the red overload 
alarm may damage the generator. Marginal overloading that 
temporarily lights the red overload alarm may shorten the service life 
of the generator.

Eco Throttle System

With the switch in the ON 
position, engine speed is 
automatically lowered when 
electrical loads are reduced, 
turned off, or disconnected. 
When appliances are turned on 
or reconnected, the engine 
returns to the proper speed to 
power the electrical load. In the 
OFF position, the Eco Throttle 
system does not operate and 
the engine runs at high speed.
Appliances with large start-up power demands may not allow the 
engine to reach normal operating rpm when they are connected to the 
generator. Turn the Eco Throttle switch to the OFF position and 
connect the appliance to the generator. If the engine still will not reach 
normal operating speed, check that the appliance does not exceed 
the rated load capacity of the generator.
If high electrical loads are connected simultaneously, turn the Eco 
Throttle switch to the OFF position to reduce voltage changes.
The Eco Throttle system is not effective for use with appliances or 
tools that require only momentary power. If the tool or appliance will 
be turned ON and OFF quickly, the Eco Throttle switch should be in 
the OFF position.

CHOKE 
ROD

OPEN

CLOSED

ENGINE 
SWITCH

OFF

ON

OFF

FUEL VALVE 
LEVER

ECO-THROTTLE 
SWITCH

OFF

ON

Summary of Contents for EG2800i

Page 1: ...Air Index 16 Controls 6 Air Cleaner 12 Specifications 16 Features 6 Spark Plug 12 Wiring Diagram 17 OPERATION 7 Sediment Cup Cleaning 13 AVOIDING FUEL RELATED PROBLEMS 18 Safe Operating Instructions 7...

Page 2: ...table power requirements Other uses can result in injury to the operator or damage to the generator and other property Most injuries or property damage can be prevented if you follow all the instructi...

Page 3: ...ignite some materials Keep the generator at least 3 feet 1 meter away from buildings and other equipment during operation Do not enclose the generator in any structure Keep flammable materials away f...

Page 4: ...ctane rating of 86 or higher containing no more than 10 ethanol E10 or 5 methanol by volume Refer to page 11 for additional fuel recommendations 1 Remove the fuel tank cap 2 Add fuel slowly to prevent...

Page 5: ...for signs of damage Check each control for proper operation Check that all nuts bolts and screws are tightened Check the air filter page 12 and oil level page 11 Check the fuel level page 7 Starting w...

Page 6: ...OFF position to reduce voltage changes ON Recommended to minimize fuel consumption and further reduce noise levels when less than a full load is applied to the generator OFF The Eco Throttle system d...

Page 7: ...ings and other equipment Do not operate the generator in an enclosed structure Do not place flammable objects close to the engine or locate the generator near flammable materials Starting the Engine T...

Page 8: ...wer cord can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately Disconnect the appliance and determine whet...

Page 9: ...able to your individual needs and use Remember that an authorized Honda servicing dealer knows your generator best and is fully equipped to maintain and repair it To ensure the best quality and reliab...

Page 10: ...able failures Item Action Before each use 5 hours of use or first month 25 hours of use or every 3 months 50 hours of use or every 6 months 100 hours of use or every year 250 hours of use or every 2 y...

Page 11: ...e DISTRIBUTOR S LIMITED WARRANTY If your equipment will be used on an infrequent or intermittent basis please refer to the fuel section of the STORAGE chapter page 13 for additional information regard...

Page 12: ...inside Never try to brush off dirt brushing will force dirt into the fibers 5 Foam Air Filter Wash the foam air filter in a solution of household detergent and warm water then rinse thoroughly or wash...

Page 13: ...el Position the generator so that its base is level on the bed of the transport vehicle Tie the generator down with rope or straps Keep the tie down rope or straps away from the controls Do not operat...

Page 14: ...cover A nonporous cover will trap moisture around the generator promoting rust and corrosion Removing from Storage Check your generator as described in BEFORE EACH USE on page 5 If the engine cylinder...

Page 15: ...ontrol systems to reduce the emissions of carbon monoxide oxides of nitrogen and hydrocarbons Additionally Honda fuel systems utilize components and control technologies to reduce evaporative emission...

Page 16: ...tended 300 hours 0 80 cc 500 hours greater than 80 cc 1000 hours 225 cc and greater EG2800i Lightweight inverter generator with Eco Throttle Length 16 9 in 430 mm Width 17 6 in 448 mm Overall height 1...

Page 17: ...17 Wiring Diagram...

Page 18: ...k it before each use A properly maintained air filter will help prevent dirt from entering the carburetor The small passages inside the carburetor can become blocked 3 to 4 Weeks Before Next Use Reaso...

Page 19: ...detailed description of the problem Honda Publications These publications will give you information for maintaining and repairing your generator Owner s Manual Keep this owner s manual handy so you c...

Page 20: ...w limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions and limitations may not apply to you...

Page 21: ...place other engine components damaged by a failure of any warranted part during the warranty period The use of replacement parts not equivalent to the original parts may impair the effectiveness of yo...

Page 22: ...22 NOTES...

Page 23: ...ne Complete and mail the postage paid card shown below Complete and submit the on line form at powerequipment honda com Scan the QR code below and then complete and submit the on line form commercial...

Page 24: ...ick Submit It s that simple Power Equipment Division American Honda Motor Co Inc 4900 Marconi Dr Alpharetta GA 30005 9956 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Product Registration BUSIN...

Reviews: