background image

DIC F101

Black

00X31-Z07-8000_EB2000i  Cover1-4

 2e

 KH 10.2013.02

 

 

 

Printed in Japan

31Z07800
00X31-Z07-8000

o

2013 Honda Motor Co., Ltd. -All Rights Reserved

GENERATOR

EB2000i

Owner’s Manual

See page 78 for

Initial Use Instructions

00X31-Z07-8000̲EB2000i̲Cover.indd   1

00X31-Z07-8000̲EB2000i̲Cover.indd   1

2013/01/15   13:38:23

2013/01/15   13:38:23

Click to Save File

Summary of Contents for EB2000i

Page 1: ...pan 31Z07800 00X31 Z07 8000 o2013 Honda Motor Co Ltd All Rights Reserved GENERATOR EB2000i Owner s Manual See page 78 for Initial Use Instructions 00X31 Z07 8000 EB2000i Cover indd 1 00X31 Z07 8000 EB...

Page 2: ...in this publication were in effect at the time of approval for printing Honda Motor Co Ltd reserves the right however to discontinue or change specifications or design at any time without notice and w...

Page 3: ...tended to help you avoid damage to your generator other property or the environment We suggest you read the Distributor s Limited Warranty see page 68 to fully understand its coverage and your respons...

Page 4: ...your own good judgment You will find important safety information in a variety of forms including Safety Labels on the generator Safety Messages preceded by a safety alert symbol and one of three sig...

Page 5: ...COMPONENT CONTROL LOCATIONS 10 CONTROLS 12 Engine Switch 12 Starter Grip 12 Fuel Filler Cap Vent Lever 13 Choke Lever 13 Eco Throttle Switch 14 Ground Fault Circuit Interrupter GFCI Receptacle 15 FEAT...

Page 6: ...32 SERVICING YOUR GENERATOR 33 THE IMPORTANCE OF MAINTENANCE 33 MAINTENANCE SAFETY 34 Safety Precautions 34 MAINTENANCE SCHEDULE 35 REFUELING 36 FUEL RECOMMENDATIONS 38 ENGINE OIL LEVEL CHECK 39 ENGI...

Page 7: ...Altitude Operation 60 Emission Control System Information 61 Air Index 63 Specifications 64 Wiring Diagram 65 CONSUMER INFORMATION 66 Dealer Locator Information 66 Honda Publications 66 Customer Servi...

Page 8: ...ion Do not let children operate the generator without parental supervision Carbon Monoxide Hazards A generator s exhaust contains toxic carbon monoxide which you cannot see or smell Breathing carbon m...

Page 9: ...l components that could result in electrocution Do not connect to a building s electrical system unless an isolation switch has been installed by a qualified electrician Fire and Burn Hazards The exha...

Page 10: ...LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury Read them carefully If a label comes off or becomes hard to read contact your Honda servicing dealer for a rep...

Page 11: ...9 GENERATOR SAFETY 31Z398000 book 9...

Page 12: ...dentify the most frequently used controls ECO THROTTLE SWITCH AC RECEPTACLES GFCI TEST BUTTON GFCI RESET BUTTON GROUND TERMINAL FUEL FILLER CAP VENT LEVER FUEL FILLER CAP ENGINE SWITCH STARTER GRIP MA...

Page 13: ...11 CONTROLS FEATURES SPARK PLUG MAINTENANCE COVER MUFFLER SPARK PLUG FRAME SERIAL NUMBER AIR CLEANER 31Z398000 book 11...

Page 14: ...he fuel valve ON Running position opens the fuel valve and allows the engine to be started Starter Grip Pulling the starter grip operates the recoil starter to start the engine Do not allow the starte...

Page 15: ...in the OFF position to reduce the possibility of fuel leakage Allow the engine to cool before turning the fuel filler cap vent lever to the OFF position Choke Lever The choke is used to provide proper...

Page 16: ...rns to the proper speed to power the electrical load If high electrical loads are connected simultaneously turn the Eco Throttle switch to the OFF position to reduce voltage changes ON Recommended to...

Page 17: ...n contact with an electrical ground such as a plumbing fixture wet floor or earth The GFCI will not protect against short circuit or overloads GFCIs can be expected to interrupt power supply if there...

Page 18: ...tal non current carrying parts of the generator and the ground terminals of each receptacle Before using the ground terminal consult a qualified electrician electrical inspector or local agency having...

Page 19: ...at the receptacles In addition the output indicator has a simplified hour meter function When you start the engine the indicator blinks according to the generator s cumulative operating hours as follo...

Page 20: ...o run Oil Alert Indicator The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe...

Page 21: ...o not exceed the generator s load rating see page 30 IS YOUR GENERATOR READY TO GO For your safety to ensure compliance with environmental regulations and to maximize the service life of your equipmen...

Page 22: ...n the OFF position Check the Engine Before each use look around and underneath the engine for signs of oil or gasoline leaks Check the engine oil level see page 39 A low engine oil level will cause th...

Page 23: ...50 meters and do not use multiple tools and appliances with built in noise filters Such use may activate the GFCI Make sure that the appliance is in good working order Faulty appliances or power cord...

Page 24: ...les open and clear of debris mud water etc Cooling holes are located on the side panel the control panel and the bottom of the generator If the cooling holes are blocked the generator may overheat and...

Page 25: ...be required for warm up 4 To start a cold engine move the choke lever to the CLOSED position To restart a warm engine leave the choke lever in the OPEN position 5 Turn the engine switch to the ON pos...

Page 26: ...to prevent damage to the starter 7 If the choke lever was moved to the CLOSED position to start the engine gradually move it to the OPEN position as the engine warms up 8 If you wish to use the Eco T...

Page 27: ...ormal conditions use the following procedure 1 Turn off or disconnect all appliances that are connected to the generator 2 Turn the engine switch to the OFF position 3 Allow the engine to cool and the...

Page 28: ...tton should extend If the GFCI does not function as described contact an authorized Honda generator dealer A faulty GFCI can cause electric shock which can seriously injury or kill you Always perform...

Page 29: ...xtends during operation Unplug all appliances from the GFCI protected receptacle Press the RESET button If the GFCI can not be reset the GFCI is faulty Contact an authorized Honda generator dealer If...

Page 30: ...than their electrical rating for startup When an electric motor is started the overload alarm indicator red may come ON This is normal if the overload alarm indicator red goes OFF within 4 seconds If...

Page 31: ...alarm indicator red will go ON The overload alarm indicator red will stay ON and after about four seconds current to the connected appliance s will shut off and the output indicator green will go OFF...

Page 32: ...ppliance or the rated load capacity of the generator has been exceeded Most appliance motors require more than their rated wattage for startup Make sure the electrical rating of the tool or appliance...

Page 33: ...cted to the generator Turn the Eco Throttle switch to the OFF position and connect the appliance to the generator If the engine still will not reach normal operating speed check that the appliance doe...

Page 34: ...onda EB2000i generator has a system ground that connects generator frame components to the ground terminals at the AC output receptacles The system ground is connected to the AC neutral wire Special R...

Page 35: ...tained high load or high temperature operation or use it in dusty conditions consult your servicing dealer for recommendations applicable to your individual needs and use Remember that an authorized H...

Page 36: ...en windows or doors Burns from hot parts Let the engine and exhaust system cool before touching Injury from moving parts Do not run the engine unless instructed to do so Read the instructions before y...

Page 37: ...his maintenance schedule could result in non warrantable failures Each use First month or 20 Hrs Every 3 months or 50 Hrs Every 6 months or 100 Hrs Every year or 200 Hrs Page Engine oil Check level o...

Page 38: ...Refuel carefully to avoid spilling fuel Do not fill the fuel tank above the upper level mark red on the fuel filter Never refuel the engine inside a building where gasoline fumes may reach flames or s...

Page 39: ...37 SERVICING YOUR GENERATOR After refueling tighten the fuel filler cap until it clicks FUEL FILLER CAP UPPER LEVEL MARK RED TETHER FUEL FILTER 31Z398000 book 37...

Page 40: ...contain cosolvents and corrosion inhibitors Use of fuels with content of ethanol or methanol greater than shown above may cause starting and or performance problems It may also damage metal rubber an...

Page 41: ...OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped 1 Loosen the maintenance cover screw and remove the maintenance cover MAINTENANCE COVER SCREW M...

Page 42: ...page 42 4 Reinstall the oil filler cap securely 5 Reinstall the maintenance cover and tighten the maintenance cover screw securely The Oil Alert system will automatically stop the engine before the o...

Page 43: ...toward the oil filler neck Improper disposal of engine oil can be harmful to the environment If you change your own oil please dispose of the used oil properly Put it in a sealed container and take i...

Page 44: ...30 is recommended for general use Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range The SAE oil viscosity and service category...

Page 45: ...outer filters from the air cleaner case 4 Check the main and outer filters to be sure they are clean and in good condition If the main and outer filters are dirty clean them as described on page 45 R...

Page 46: ...8 Reinstall the maintenance cover and tighten the maintenance cover screw securely Operating the engine without the air filters or with a damaged air filters will allow dirt to enter the engine causi...

Page 47: ...lean the air filters in warm soapy water rinse and allow to dry thoroughly or clean in nonflammable solvent and allow to dry 2 Dip the air filters in clean engine oil and then squeeze out all excess o...

Page 48: ...t be properly gapped and free of deposits An incorrect spark plug can cause engine damage If the engine is hot allow it to cool before servicing the spark plug 1 Remove the spark plug maintenance cove...

Page 49: ...lug in by hand to prevent cross threading 8 After the spark plug is seated tighten with a spark plug wrench to compress the sealing washer If reinstalling a used spark plug tighten 1 8 1 4 turn after...

Page 50: ...ffler will be very hot Allow the muffler to cool before servicing the spark arrester Clean the spark arrester as follows 1 Remove the four 6 mm screws and remove the muffler protector 2 Remove the thr...

Page 51: ...l to avoid damaging the screen The spark arrester must be free of breaks and tears Replace the spark arrester if it is damaged 4 Check the muffler gasket replace if damaged Reinstall the muffler gaske...

Page 52: ...starting and it leaves gum deposits that clog the fuel system If the gasoline in your generator deteriorates during storage you may need to have the carburetor and other fuel system components servic...

Page 53: ...asoline and add gasoline stabilizer Turn the engine switch to the OFF position and drain the carburetor float bowl see page 52 1 year or more Drain the fuel tank and carburetor see page 53 Change the...

Page 54: ...and drain the gasoline from the carburetor into a suitable container 3 Tighten the carburetor drain screw Gasoline is highly flammable and explosive You can be burned or seriously injured when handlin...

Page 55: ...and drain the gasoline from the carburetor into a suitable container 4 Remove the spark plug maintenance cover and the spark plug cap see page 46 5 Turn the engine switch to the ON position see page...

Page 56: ...distribute the oil and then reinstall the spark plug 3 Reinstall the spark plug cap on the spark plug securely 4 Reinstall the spark plug maintenance cover 5 Reinstall the maintenance cover and tighte...

Page 57: ...y of leakage Place the generator on a level surface Tilting or laying it on its side can cause fuel or oil leakage With the engine and exhaust system cool cover the generator to keep out dust A hot en...

Page 58: ...ort vehicle A hot engine and exhaust system can burn you and can ignite some material To prevent fuel spillage when transporting the generator should be secured upright in its normal operating positio...

Page 59: ...line Drain fuel tank and carburetor see page 53 Refuel with fresh gasoline see page 36 Low engine oil level caused Oil Alert to stop engine Turn the engine switch to the OFF position Add engine oil Th...

Page 60: ...restricted carburetor malfunction ignition malfunction valves stuck etc Take the generator to an authorized Honda servicing dealer or refer to the shop manual Possible Cause Correction Output indicat...

Page 61: ...on Record the frame serial number and date purchased in the spaces below You will need this information when ordering parts and when making technical or warranty inquiries Frame serial number Date pur...

Page 62: ...ler perform this carburetor modification This engine when operated at high altitude with the carburetor modifications for high altitude use will meet each emission standard throughout its useful life...

Page 63: ...hnologies to reduce evaporative emissions The U S and California Clean Air Acts EPA and California regulations require all manufacturers to furnish written instructions describing the operation and ma...

Page 64: ...re manufactured to the same standards as the original parts so you can be confident of their performance The use of replacement parts that are not of the original design and quality may impair the eff...

Page 65: ...tion The durability description is intended to provide you with information relating to the engine s emission durability period The descriptive term indicates the useful life period for the engine s e...

Page 66: ...ompression ratio 8 5 1 Engine speed 4 300 5 000 rpm with Eco Throttle switch OFF Cooling system Forced air Ignition system Full transistor Engine oil capacity 13 oz 0 40 L Fuel tank capacity 0 95 US g...

Page 67: ...LOCK OFF ON OFF Switch position ON COLOR COMB GROUND MARKING Bl BLACK Br BROWN Y YELLOW O ORANGE Bu BLUE Lb LIGHT BLUE G GREEN Lg LIGHT GREEN R RED P PINK W WHITE Gr GRAY INVERTER UNIT INVERTER BLOCK...

Page 68: ...or visit http powerequipment honda com support shop manuals Parts Catalog This manual provides complete illustrated parts lists Available through your Honda dealer Accessories Catalog Your authorized...

Page 69: ...d with the decision made by the dealership s management contact the Honda Power Equipment Customer Relations Office You can write American Honda Motor Co Inc Power Equipment Division Customer Relation...

Page 70: ...products This warranty applies to the first retail purchaser and each subsequent owner during the applicable warranty time period What American Honda will Repair or Replace Under Warranty American Hon...

Page 71: ...business hours To locate a dealer near you visit our web site at http powerequipment honda com dealer locator If you are unable to obtain warranty service or are dissatisfied with the warranty service...

Page 72: ...tire wheel bearing recoil starter rope cable belt cutter blade Lubricant oil and grease 3 Cleaning adjustment and normal periodic maintenance work carburetor cleaning engine oil draining blade sharpen...

Page 73: ...ent accessories replacement parts or apparel that are proven to be defective in material or workmanship under normal use during the applicable warranty time period Anything replaced under warranty bec...

Page 74: ...is warranty does not extend to accessories parts or apparel affected or damaged by collision normal wear use in an application for which the product was not designed or any other misuse neglect incorp...

Page 75: ...ipped to meet the State s stringent anti smog standards Other States U S territories and Canada In other areas of the United States and in Canada your engine must be designed built and equipped to mee...

Page 76: ...a part has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for presenting your power equipment engine to a Honda Power Equipment dealer as soon as a pr...

Page 77: ...tems such as spark plugs and filters that are on the warranted parts list are warranted up to their required replacement interval only Honda will also replace other engine components damaged by a fail...

Page 78: ...office in your region Exclusions Failures other than those resulting from defects in material or workmanship are not covered by this warranty This warranty does not extend to emission control systems...

Page 79: ...n Honda parts Covered up to the first required replacement only See the MAINTENANCE SCHEDULE on page 35 SYSTEMS COVERED BY THIS WARRANTY PARTS DESCRIPTION Fuel Metering Carburetor assembly includes st...

Page 80: ...ring the oil level to the upper limit of the oil filler neck SAE 10W 30 oil is recommended for general use for additional recommendations see page 42 Maximum oil capacity 13 oz 0 40 L Do not overfill...

Page 81: ...a fire hazard it causes environmental damage Wipe up spills immediately This engine is certified to operate on unleaded gasoline with a pump octane rating of 86 or higher Refer to page 38 for addition...

Page 82: ...fill the fuel tank above the upper level mark red on the fuel filter Fuel can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not co...

Page 83: ...0 feet 3 meters away from the fueling source and site before starting the engine After initial fueling or anytime the generator is run completely out of fuel starting the engine may require additional...

Page 84: ...Please Register Your Generator If your dealer did not collect registration information from you please take a few minutes and register your purchase with Honda This allows us to contact you with any...

Page 85: ...Carburetor Modification for High Altitude Operation 60 Check the Engine 20 Choke Lever 13 Cleaning 50 COMPONENT CONTROL LOCATIONS 10 Connections to a Building s Electrical System 32 CONSUMER INFORMAT...

Page 86: ...HECK 39 ENGINE OIL RECOMMENDATIONS 42 Engine Switch 12 ENGINE WILL NOT START 57 F FEATURES 16 Fire and Burn Hazards 7 Fuel 50 79 Fuel Filler Cap Vent Lever 13 FUEL RECOMMENDATIONS 38 G GENERATOR SAFET...

Page 87: ...SCHEDULE 35 N NO POWER AT THE AC RECEPTACLES 58 O Oil Alert Indicator 18 OPERATION 21 Operator Responsibility 6 Output Indicator 17 Overload Indicator 18 Q QUICK REFERENCE INFORMATION Inside back cov...

Page 88: ...SPARK PLUG SERVICE 46 Special Requirements 32 Specifications 64 STANDBY POWER 32 Starter Grip 12 STARTING THE ENGINE 22 STOPPING THE ENGINE 25 STORAGE 50 STORAGE PRECAUTIONS 55 STORAGE PREPARATION 50...

Page 89: ...87 MEMO 31Z398000 book 87...

Page 90: ...88 MEMO 31Z398000 book 88...

Page 91: ...in this publication were in effect at the time of approval for printing Honda Motor Co Ltd reserves the right however to discontinue or change specifications or design at any time without notice and w...

Page 92: ...39800 00X31 Z39 8000 2013 Honda Motor Co Ltd All Rights Reserved GENERATOR EB2000i Owner s Manual See page 78 for Initial Use Instructions H i FM C AH EB2000i OMcover 31Z39800 F EB2000i OMcover 31Z398...

Reviews: