BEFORE OPERATION
44
AIR FILTER CHECK
1. Open the maintenance cover to access the air cleaner.
2. Pull the air cleaner cover latch to the unlocked position, and remove the
cover.
Remove the wing nut from the paper filter element.
Remove the paper filter element and foam filter element from the air cleaner
case.
Remove the foam filter element from the paper filter element.
3. Inspect both filter elements, and replace them if they are damaged. Always
replace the paper filter element at the scheduled interval (see page 66).
MAINTENANCE COVER
AIR CLEANER COVER LATCH
AIR CLEANER COVER
PAPER FILTER ELEMENT
AIR CLEANER CASE
WING NUT
FOAM FILTER ELEMENT
AIR CHAMBER
PACKING