38
Servicing Your Honda
Subframe
11. Remove the starter relay switch stay bolt (16)
and plastic wire band (17).
Pull out the starter relay switch (18).
Remove the starter relay switch cover (19) and
then disconnect the starter relay switch
connector (20).
Remove the starter motor terminal bolt (21)
and disconnect the starter motor terminal (22)
from the starter relay switch.
12. Remove the subframe lower bolts (23) and
upper bolts (24).
Remove the subframe (10) while
disconnecting the air cleaner box (25).
Installation
1. Loosely attach the upper and lower ends of the
subframe to the main frame and loosely install
all subframe bolts.
2. Tighten the subframe upper bolts (1) first and
then tighten the lower bolts (2) to the specified
torque:
subframe upper bolts:
24 lbf·ft (32 N·m, 3.3 kgf·m)
subframe lower bolts:
36 lbf·ft (49 N·m, 5.0 kgf·m)
(16) starter relay switch stay bolt
(17) plastic wire band
(18) starter relay switch
(19) starter relay switch cover
(20) starter relay switch connector
(21) starter motor terminal bolt
(22) starter motor terminal
(16)
(17)
(20)
(18)
(19)
(21)
(22)
(10) subframe
(23) subframe lower bolts
(24) subframe upper bolts
(25) air cleaner box
(10)
(23)
(24)
(25)
(24)
(23)
(1) subframe upper bolts
(2) subframe lower bolts
Left side:
Right side:
(1)
(2)
(2)
(1)