Honda Motorcycle & Scooter India Pvt. Ltd.
50
2. Operate the kickstarter several times
to aid in complete draining of the
remaining oil.
3. Check that the sealing washer on the
drain bolt is in good condition and install
the bolt. Replace the sealing washer
every other time the oil is changed, or
each time if necessary.
Oil Drain Bolt Torque:
30 N·m (3.1 kgf·m , 22 lbf·ft)
4. Fill the crankcase with the recommended
grade oil; approximately:
1.0 L (1.0 US qt , 0.9 Imp qt)
5. Install the oil filler cap/dipstick.
6. Start the engine and let it idle for 3-5
minutes.
7. 2-3 minutes after stopping the engine,
check that the oil level is at the upper
level mark on the oil filler cap/dipstick
with the vehicle upright on firm, level
ground. Make sure there are no oil
leaks.
CRANKCASE BREATHER
Refer to the Safety Precautions on page 42.
1. Remove the left side cover (page 33).
2. Remove the crankcase breather tube
plug (1) from the tube and drain
deposits into a suitable container.
(1) Crankcase breather tube plug
¼ØSaddsl czhnj V~;wc Iyx½
(1)
3. Reinstall the crankcase breather tube
plug.
Service more frequently when riding in rain
or at full throttle.