OPERATION
PUMP PLACEMENT
Always position the pump in an upright position on a firm level surface
at least 3 feet (1 meter) away from any walls or other equipment.
For best pump performance, place the pump near the water level, and
use hoses that are no longer than necessary. That will enable the
pump to produce the greatest output with the least self-priming time.
As
head
(pumping height) increases, pump output decreases.
Maximum head specifications are shown in the tables on page 62. The
length, type, and size of the suction and discharge hoses can also
significantly affect pump output.
Discharge head capability is always greater than suction head
capability, so it is important for suction head to be the shorter part of
total head.
The maximum available suction head will vary based on the operating
conditions. However, the suction head can never exceed 26 feet
(8 meters) and should always be kept as low as possible.
Minimizing suction head (placing the pump near the water level) is
also very important for reducing self-priming time. Self-priming time
is the time it takes the pump to bring water the distance of the suction
head during initial operation.
TOTAL
HEAD
At least 3 feet (1 meter)
DISCHARGE
HEAD
SUCTION HEAD
LESS THAN
26 feet
(8 meters)