2002 American Honda Motor Co., Inc – All Rights Reserved
18 of 24
AII 24158 (0209)
19. Install the condenser and receiver lines.
Apply refrigerant
oil to both fittings on
the condenser line,
then install the line
between the receiver
and condenser.
Secure the condenser line to
the receiver with one 6 x 25
mm flange bolt (yellow-tinted),
95701-06025-08. Torque the
bolt to 10 N
.
m (7 lb-ft).
Apply refrigerant oil
to its fitting, then
connect the receiver
line to the receiver
with one 6 x 25 mm
flange bolt
(yellow-tinted),
95701-06025-08.
Torque the bolt to
10 N
.
m (7 lb-ft).
Install receiver
line clip B
(80387-SM4-A01)
into this square
hole.
Install receiver line clip A
(80381-S5A-A01) into
this square hole.
Secure the condenser
line to the condenser
with one 6 x 25 mm
flange bolt (yellow-tinted),
95701-06025-08. Torque
the bolt to 10 N
.
m (7 lb-ft).
Install the compressor on the
compressor bracket with the
four 8 x 100 mm flange bolts
(90023-P2A-000). Torque
the bolts to 24 N
.
m (17lb-ft).
Secure the
condenser fan
assembly with two
6 x 16 mm washer-
bolts (gray-colored),
93403-06016-05.
Torque the bolts to
10 N
.
m (7 lb-ft).
20. Install the compressor and the condenser fan.
FRONT
Carefully set the
condenser fan
assembly in place
on the condenser
fan mounts.