1-10
6. THERMOSTAT
1. Installing the thermostat seal in the kit.
i)
Remove the thermostat to circulate cooling water better.
•
A thermostat rubber is used as a thermostat cover in place of a gasket, therefore, a seal should
be the same thickness as a thermostat.
Thermostat seal:
19300-NKD-970
ii)
Set the thermostat seal, then tighten the cover with the rubber adjusted.
Tightening torque: 1.0kgf.m
7, A.C. GENERATOR
1. Installing the A.C. generator in the kit
i)
Remove the L. crankcase cover.
ii)
Remove the standard flywheel with specialist tool.
Flywheel puller: 07733-0010000
Flywheel puller attachment:07HMC-KV30100
iii)
Remove the starter with a hexagonal wrench.
iv)
Install the A.C. generator in the kit.
•
Exchange the cap bolt 6x32 for 6x18 to fix the starter.
Tightening torque socket bolt 1.2 kgf.m
•
Fix crankcase cover.
Tightening torque socket bolt 1.2 kgf.m
[CAUTION]
•
Remodelling the crankcase cover to change the final drive is not allowed.