background image

2.

INTRODUCTION

MORI HR NEXT is a alternate flow fan with heat retention, designed to ensure adequate ventilation in enclosed environments without energy losses.

It is recommended that two units are installed in a pair: when one unit is extracting, the other is supplying air.

The pair of units can be installed in the same room or in different rooms (i.e. living-room and bedroom). The unit is suitable for installation on an outside 

wall.

The unit should operate continuously, and only stopped for maintenance or service.

When heat exchange is not useful (for example in mid-seasons when indoor and outdoor temperatures are similar), or when heat 
exchange is not recommended (for example with the option “summer free cooling”), it is recommended to set the unit in “extract-only” 
or “intake-only” mode and NOT to switch it off.

Technical Specifications

• 

Design front cover (A) removable for cleaning without the use of tools.

• 

Inner ventilation unit (B) and wall support base (D) made of high quality, impact and UV-resistant ABS, colour RAL 9010.

• 

Integrated multi-colour led (C ) to obtain a visual feedback of the unit status.

• 

Smart humidity control.

• 

Integral temperature sensor for the automatic management of the inversion time (comfort mode).

• 

Automatic anti-frost protection to prevent frost building up on the heat exchanger.

• 

Wall support base (D) provided with a magnet “coupling/uncoupling” system which allows the ventilation unit to be removed from its base 

during maintenance.

• 

Back-up touch button (E) at the side of the ventilation unit.

• 

Unique design winglet-type impeller, providing enhanced aerodynamic properties, low noise and increased efficiency.

• 

High efficient reversible EC motor with integral thermal protection, mounted on sealed for life high quality ball bearings.

• 

Designed for continuous reversible running.

• 

Telescopic pipe (F) adaptable to the wall thickness.

• 

Antimortar cap designed to be used also as template during the installation of the wall support base.

• 

Regenerative heat exchanger with ceramic core (G) with high thermal efficiency, equipped with washable anti-dust filters (H).

• 

External grille (I) made of high quality, impact and UV-resistant ABS, colour RAL 9010, with anti-insect net and water drip guard.

• 

Infra-red remote controller with touch technology, LCD display and wall base supplied as standard. Made from ABS, RAL 9010.

• 

The unit is double insulated: no earth connection is required.

• 

No need of condensation drainage system.

• 

IPX4 degree of protection.

• 

Power supply 220V to 240V~ 50Hz.

Summary of Contents for MORI HR NEXT

Page 1: ...cting the product to the power supply or the power outlet ensure that the data plate voltage and frequency correspond to those of the electrical mains the electrical power supply socket is adequate for maximum device power If not contact a qualified technician The device should not be used as an activator for water heaters stoves etc nor should it discharge into hot air fume vent ducts deriving fr...

Page 2: ...mperature sensor for the automatic management of the inversion time comfort mode Automatic anti frost protection to prevent frost building up on the heat exchanger Wall support base D provided with a magnet coupling uncoupling system which allows the ventilation unit to be removed from its base during maintenance Back up touch button E at the side of the ventilation unit Unique design winglet type...

Page 3: ...red to the unit anytime a touch button is pressed the setting shown on the LCD display is transferred to the unit The IR receiver J image pag 7 is placed on the left side of the ventilation unit it is recommended to point the controller towards the receiver when any setting needs to be transfered One remote controller can control more units To activate the remote controller it is necessary to inse...

Page 4: ...y button OFF Red Long BOOST speed The unit runs at speed 5 maximum for 15 minutes in extract only then it returns to the previously selected mode speed The BOOST speed cannot be activated if the controller is OFF Fixed Blue Short Free Cooling The unit runs in extract only or intake only to avoid heat recovery when not needed oppure Green Short Filter reset Every 3 months a yellow warning LED switc...

Page 5: ...neously through wire 2 pole twisted pair type max 30m length so to have mode and inversion time synchronized When the unit is switched on for the first time the rotation direction of each unit clockwise or anti clockwise is automatically established Other functionalities like speed smart humidity control and boost continue to be controlled independently on each single unit Wiring diagram as per Fi...

Page 6: ...on Data Date Firma Sign TS Progetti ARCHIVIO CAD AQD 01178 00 003036 1 1 No Dis No Drawing Codice Code Scala Scale Peso Weight 124 44 26 5 117 5 39 23 39 23 117 5 Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright Nè è vietata la copia la diffusione senza autorizzazione di Aerauliqa srl This document is protected by privacy and copyright laws No part of this document...

Page 7: ...7 5 10 6 11 7 13 14 15 12 RECESSED CABLE ENTRY H03VV F H05VV F 2 X 0 5 1 5 mm2 8 9 ...

Page 8: ...8 16a 17 16b 18 21 22 19 20 ...

Page 9: ...9 SURFACE CABLE for one unit wiring H03VV F H05VV F 2 X 0 5 1 5 mm2 23 24 25 26 27 28 29 31 32 33 30 ...

Page 10: ...10 34 37 38 40 39 41 35 36 42 43 44 REMOTE CONTROLLER WALL MOUNTING ...

Page 11: ...11 45 46 49 50 51 47 48 EXTERNAL GRILLE MAINTENANCE ...

Page 12: ...12 52 53 54 55 61 62 63 56 57 59 60 58 ...

Page 13: ...wn Wait until the boost timing ends 15 minutes or deactivate the boost function pressing the button Unit speed suddenly increases The smart humidity control is activated Wait until the smart humidity control phase ends 10 minutes or deactivate the humidity control function pressing the button for 5 seconds Fixed yellow led Dirty filters Filters maintenance replacement is needed reset filter operat...

Page 14: ...0 08 n1 Fattore di controllo Control factor 0 65 n2 Control typology Local demand control o1 Maximum internal leakage rate N A o2 Maximum external leakage rate 1 p1 Internal mixing rate N A p2 External mixing rate N A q Visual filter warning N A r Instructions to install regulated grilles N A s Internet address for preassembly disassembly instructions www homevent co uk t Airflow sensitivity to pr...

Page 15: ...tes the recycling of the materials that make up the equipment Improper disposal of the product by the user may result in administrative sanctions as provided by law WARRANTY Our 5 year warranty is provided only to customers who purchased directly from us If you purchased elsewhere then please contact them directly and they will let you know their warranty procedure Our warranty covers repair or re...

Page 16: ...MORI HR NEXT ISSUE A 03 21 Tel 44 0 1384 275822 Email sales homevent co uk 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US UK www homevent co uk ...