Troubleshooting

Fast orange 
flashing

Pairing mode 
of both devices 
active 
(pairing)

Wait for confir-
mation of the 
device LED (see 
sec. „7.3 Error 
codes and flash-
ing sequences“ 
on page 51).

1x long red 
lighting

Transmission 
failed or duty 
cycle limit is 
reached

Please try again 
(see sec. „7.1 
Command not 
confirmed“ on 
page 50 or 
„7.2 Duty cycle“ 
on page 50).

6x long red 
flashing

Device defective Please see your 

app for error 
message or 
contact your 
retailer.

1x orange and 1 
x green lighting

Test display

Once the test 
display has 
stopped, you 
can continue.

Summary of Contents for HmIP-WHS2

Page 1: ...Montage und Bedienungsanleitung Mounting instruction and operating manual Schaltaktor f r Heizungsanlagen 2 fach S 2 Actuator for heating systems 2 channels p 25 HmIP WHS2...

Page 2: ...ktronischer mechanischer oder chemischer Verfahren verviel f ltigt oder verarbeitet werden Es ist m glich dass die vorliegende Anleitung noch drucktech nische M ngel oder Druckfehler aufweist Die Anga...

Page 3: ...1 A C D F E B G...

Page 4: ...2 3...

Page 5: ...4 5 89 mm 67 mm...

Page 6: ...lussm glichkeiten 18 6 3 1 Anschluss Kessel 18 6 3 2 Anschluss Luftentfeuchter 19 6 3 3 Anschluss Change Over Pilot 20 6 3 4 Anschluss Pumpe 21 6 4 Anlernen 22 7 Fehlerbehebung 24 7 1Befehl nicht best...

Page 7: ...sen bergeben Sie auch diese Anleitung Benutzte Symbole Achtung Hier wird auf eine Gefahr hingewiesen Hinweis Dieser Abschnitt enth lt zus tzliche wichtige Informationen 2 Gefahrenhinweise ffnen Sie da...

Page 8: ...ichen Spielzeug werden Bei Sach oder Personenschaden die durch un sachgem e Handhabung oder Nichtbeachten der Gefahrenhinweise verursacht werden ber nehmen wir keine Haftung In solchen F llen er lisch...

Page 9: ...fahren entstehen Beachten Sie beim Anschluss an die Ger teklem men die hierf r zul ssigen Leitungen und Lei tungsquerschnitte Beachten Sie vor Anschluss eines Verbrauchers die technischen Daten insbes...

Page 10: ...n Sie die Installationsvorschriften f r Ins tallationen in Verteilersystemen DIN VDE 0100 410 Das Ger t ist nur f r den Einsatz in wohnungs hn lichen Umgebungen geeignet Jeder andere Einsatz als der i...

Page 11: ...p nach Ihren individuellen Bed rf nissen erm glicht Das Ger t kann in Verbindung mit dem Homematic IP Access Point oder der Homematic Zentrale CCU2 z B als W rmebedarfsrelais zur Steuerung von Umw lzp...

Page 12: ...martphone ber die Homema tic IP App konfiguriert werden Alternativ haben Sie die M glichkeit Homematic IP Ger te ber die Homematic Zentrale CCU2 oder in Verbindung mit vielen Partner l sungen zu betre...

Page 13: ...in der Wand keine Leitungen verlaufen ffnen Sie die Abdeckung B indem Sie die bei den unteren Schrauben mit einem geeigneten Schraubendreher l sen und die Abdeckung ab nehmen s Abbildung 2 3 Zeichnen...

Page 14: ...der Niederspannungsverteilung erforderlich sein ist unbedingt folgender Sicherheitshinweis zu be achten Hinweis Installation nur durch Personen mit einschl gigen elektrotechnischen Kenntnissen und Erf...

Page 15: ...Sicherstellung der Abschaltbedingungen IP Schutzarten Einbau des Elektroinstallationsmaterials Art des Versorgungsnetzes TN System IT System TT System und die daraus folgenden Anschlussbedingungen kla...

Page 16: ...se 1 0 bis 2 5 mm 1 0 bis 2 5 mm Zugelassene Leitungsquerschnitte f r die Klemmen G sind Starre Leitung Flexible Leitung mit und ohne Aderendh lse 1 0 bis 1 5 mm 0 5 bis 1 0 mm Die zugelassenen Leitun...

Page 17: ...N D an Schlie en Sie den Schutzleiter an die Anschluss klemme f r PE E an Schlie en Sie z B einen Heizkessel an den Schaltkanal 1 F oder eine Umw lzpumpe an die Anschlussklemmen f r den Schaltkanal 2...

Page 18: ...18 Inbetriebnahme 6 3 Anschlussm glichkeiten 6 3 1 Anschluss Kessel PE PE L L N N 1 1 L 2 L N L...

Page 19: ...iebnahme 6 3 2 Anschluss Luftentfeuchter Diese Anschlussm glichkeit k nnen Sie nur in Verbindung mit einem Homematic IP Access Point oder einer Homematic Zentrale CCU2 reali sieren PE PE L L N N 1 1 L...

Page 20: ...3 3 Anschluss Change Over Pilot Diese Anschlussm glichkeit k nnen Sie nur in Verbindung mit einem Homematic IP Access Point oder einer Homematic Zentrale CCU2 reali sieren PE PE L L N N 1 1 L 2 L N L...

Page 21: ...21 Inbetriebnahme 6 3 4 Anschluss Pumpe PE PE L L N N 1 1 L 2 L N L...

Page 22: ...ess Point als auch an die Homematic Zentrale CCU2 anlernen Weitere Informationen dazu entnehmen Sie bitte dem Homematic IP Anwenderhandbuch zu finden im Downloadbereich unter www eQ 3 de Damit der Sch...

Page 23: ...der Ger tenummer SGTIN ein oder scannen Sie den QR Code Die Ger tenummer finden Sie auf dem Aufkleber im Lieferumfang oder direkt am Ger t Warten Sie bis der Anlernvorgang abgeschlossen ist Zur Best...

Page 24: ...eine gesetzlich geregelte Be grenzung der Sendezeit von Ger ten im 868 MHz Be reich Das Ziel dieser Regelung ist es die Funktion aller im 868 MHz Bereich arbeitenden Ger te zu gew hrleisten In dem von...

Page 25: ...s Ger tes wiederhergestellt 7 3 Fehlercodes und Blinkfolgen Blinkcode Bedeutung L sung Kurzes oranges Blinken Funk bertragung Sendeversuch Daten bertragung Warten Sie bis die bertragung beendet ist 1x...

Page 26: ...nges rotes Leuchten Vorgang fehlge schlagen oder Duty Cycle Limit erreicht Versuchen Sie es erneut 7 1 Befehl nicht be st tigt auf Seite 24 oder 7 2 Duty Cycle auf Seite 24 6x langes rotes Blinken Ger...

Page 27: ...vor Dr cken Sie f r 4 s auf die Systemtaste A bis die LED schnell orange zu blinken beginnt s Abbildung 5 Lassen Sie die Systemtaste wieder los Dr cken Sie die Systemtaste erneut f r 4 s bis die LED g...

Page 28: ...se und die Beschriftung k nnen dadurch an gegriffen werden 10 Allgemeine Hinweise zum Funkbe trieb Die Funk bertragung wird auf einem nicht exklusiven bertragungsweg realisiert weshalb St rungen nicht...

Page 29: ...3 de 11 Technische Daten Ger te Kurzbezeichnung HmIP WHS2 Versorgungsspannung 230V 50Hz Stromaufnahme 16 A max Leistungsaufnahme Ruhebetrieb 0 2 W Schutzart IP20 Umgebungstemperatur 0 bis 50 C Lastart...

Page 30: ...Verschmutzungsgrad 2 Schutzart IP20 Schutzklasse I Abmessungen B x H x T 120 x 130 x 30 mm Gewicht 165 g Funkfrequenzband 868 3 MHz 869 525 MHz Empf ngerkategorie SRD category 2 Typ Funk Freifeldreic...

Page 31: ...Elektronik Altger te ber die rtlichen Sammelstellen f r Elektronik Altger te zu entsorgen Konformit tshinweis Das CE Zeichen ist ein Freiverkehrszeichen das sich ausschlie lich an die Beh rden wendet...

Page 32: ...electronic mechanical or chemical means without the written consent of the publisher Typographical and printing errors cannot be excluded However the information contained in this manual is reviewed o...

Page 33: ...s 40 6 2 Installation 43 6 3 Connections 44 6 3 1 Boiler connection 44 6 3 2 Air dehumidifier connection 45 6 3 3 Change over pilot supply 46 6 3 4 Pump connection 47 6 4 Teaching in 48 7 Troubleshoot...

Page 34: ...e to other persons for use please hand over this manual as well Symbols used Attention This indicates a hazard Please note This section contains important ad ditional information 2 Hazard information...

Page 35: ...bility for damage to property or personal injury caused by improper use or the failure to observe the hazard informa tion In such cases any claim under warranty is extinguished For consequential damag...

Page 36: ...the device terminals take the permissible cables and cable cross sections into account Please take the technical data in particular the maximum permissible effective installed load of the device and...

Page 37: ...distribution systems DIN VDE 0100 410 The device may only be operated within residen tial buildings Using the device for any purpose other than that described in this operating manual does not fall w...

Page 38: ...he device can be used in connection with the Home matic IP Access Point or the Homematic Central Con trol Unit CCU2 e g as heat demand relay for controlling heating pumps in connection with radiator t...

Page 39: ...by the system in combination with other com ponents are described in the Homematic IP User Guide All current technical documents and updates are provided at www eQ 3 com 5 Mounting You can flexibly m...

Page 40: ...ting to install the device If changes or works have to be made on the house installation e g extension bypass of switch or socket inserts or the low voltage dis tribution for mounting or installing th...

Page 41: ...bouring live parts Select suitable tool measuring equipment and if necessary personal safety equipment Evaluation of measuring results Selection of electrical installation material for safeguarding sh...

Page 42: ...ard information in section 2 Hazard information on page 34 during in stallation Permitted cable cross sections for the connecting termi nals C F are Rigid cable Flexible cable with without ferrule 1 0...

Page 43: ...al L C Connect the neutral conductor to connecting terminal N D Connect the protective conductor to connecting terminal PE E Connect e g the boiler to connecting terminal 1 F or a circulation pump to...

Page 44: ...44 Start up 6 3 Connections 6 3 1 Boiler connection PE PE L L N N 1 1 L 2 L N L...

Page 45: ...Start up 6 3 2 Air dehumidifier connection This type of connection can be realised only in connection with a Homematic IP Access Point or Homematic Central Control Unit CCU2 PE PE L L N N 1 1 L 2 L N...

Page 46: ...6 3 3 Change over pilot supply This type of connection can be realised only in connection with a Homematic IP Access Point or Homematic Central Control Unit CCU2 PE PE L L N N 1 1 L 2 L N L N L cooli...

Page 47: ...47 Start up 6 3 4 Pump connection PE PE L L N N 1 1 L 2 L N L...

Page 48: ...omematic Central Control Unit CCU2 For detailed information please refer to the Homematic IP User Guide available for download in the download area of www eQ 3 com To integrate the switch actuator int...

Page 49: ...digits of the device number SGTIN in your app or scan the QR code Therefore please see the sticker sup plied or attached to the device Please wait until teach in is completed If teaching in was succes...

Page 50: ...cycle The duty cycle is a legally regulated limit of the transmis sion time of devices in the 868 MHz range The aim of this regulation is to safeguard the operation of all devices working in the 868 M...

Page 51: ...a short period max 1 hour 7 3 Error codes and flashing sequences Flashing code Meaning Solution Short orange flashing Radio transmis sion attempting to transmit data transfer Wait until the transmissi...

Page 52: ...on page 51 1x long red lighting Transmission failed or duty cycle limit is reached Please try again see sec 7 1 Command not confirmed on page 50 or 7 2 Duty cycle on page 50 6x long red flashing Devi...

Page 53: ...proceed as follows Press and hold down the system button A for 4 seconds until the LED quickly starts flashing or ange see fig 5 Release the system button again Press and hold down the system button a...

Page 54: ...ing and label 10 General information about radio operation Radio transmission is performed on a non exclusive transmission path which means that there is a possibil ity of interference occurring Inter...

Page 55: ...m 12 Technical specifications Device short description HmIP WHS2 Supply voltage 230V 50Hz Current consumption 16 A max Standby power consumption 0 2 W Degree of protection IP20 Ambient temperature 0 t...

Page 56: ...tion and control device Pollution degree 2 Degree of protection IP20 Protection class I Dimensions W x H x D 120 x 130 x 30 mm Weight 165 g Radio frequency 868 3 MHz 869 525 MHz Receiver category SRD...

Page 57: ...dis posed of at local collection points for waste elec tronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive Information about conformity The CE sign is a free t...

Page 58: ...m chtigter des Herstellers Manufacturer s authorised representative eQ 3 AG Maiburger Stra e 29 26789 Leer GERMANY www eQ 3 de Kostenloser Download der Homematic IP App Free download of the Homematic...

Reviews: