42
Start-up
according to VDE 0100 and HD382 or 60364
have to be considered. Users must be able to
easily access the cable protection switch. This
must be marked as disconnecting device for the
actuator.
Please observe the hazard information in section
„2 Hazard information“ on page 34 during in-
stallation.
Permitted cable cross sections for the connecting termi-
nals
C - F
are:
Rigid cable
Flexible cable with/
without ferrule
1.0 - 2.5 mm²
1.0 - 2.5 mm²
Permitted cable cross sections for the connecting termi-
nals
G
are:
Rigid cable
Flexible cable with/
without ferrule
1.0 - 1.5 mm²
0.5 - 1.0 mm²
The permitted cable diameter for all cable bushings are
8 to 11 mm.