Use only mains power capable buttons and wires for
connecting to button inputs!
Switch actuator:
Follow all technical specifications, especially the
maximum permitted switching capacity of the relay
and type of consumer to be connected, before
connecting the consumer! All load specifications
refer to resistive loads!
Blind actuator:
The actuator is only suitable for 230V a.c. motors!
Never connect three-phase a.c. motors or d.c.
motors!
If motors are connected to the output in parallel
with the actuator, make sure to observe the motor
manufacturer's specifications.
The motors can be damaged otherwise. Use only
blinds or shutters with limit switch (mechanical or
electronic)!
Check the limit switch for the connected motors for
proper adjustment before starting the blind actuator!