CARE, MAINTENANCE & CLEANING

•  Clean the blood pressure monitor body and cuff 

carefully with a slightly damp, soft cloth. Do not 

press. Do not wash cuff or use chemical cleaner on 

it. Never use thinner, alcohol or petrol (gasoline) as a 

cleaner.

•  Leaky batteries can damage the unit. Remove the 

batteries when the unit will not be used for a long 

time.

•  Follow local ordinances and recycling instructions 

regarding disposal or recycling of the device and 

device components, including batteries.

•  If the unit is stored near freezing, allow it to acclimate 

to room temperature before use.

•  This blood pressure monitor is not field serviceable. 

You should not use any tool to open the device nor 

should you attempt to adjust anything inside the 

device. If you have any problems with this device, 

please contact HoMedics Consumer Relations 

(contact information on warranty page).

•  Do not immerse the unit in water as this will result in 

damage to the unit.

23

24

•    Do not subject the monitor or cuff to extreme 

temperatures, humidity, moisture, or direct sunlight. 

Protect from dust.

• Do not fold the cuff tightly.
•  Do not disassemble the monitor or cuff. If in need of 

repair, refer to the warranty section of this manual.

•  Do not subject the monitor to extreme shocks (do not 

drop on floor).

•  Do not inflate the cuff unless wrapped around wrist.
•  Do not wrap the cuff around body parts other than 

your wrist.

• Do not drop or insert any object into any opening.
•  This monitor may not meet its performance 

specifications if stored or used outside of these 

temperature and humidity ranges:

•  Storage/Transportation  

Environment 

  Temperature: 

-13°F~158°F  
(-25°C~70°C) 
 
Humidity: 
Less than 93% RH

•  Operation  

Environment 

  Temperature: 

41°F~104°F  
(5°C ~40°C) 
 
Humidity: 
15 ~ 93% RH

Summary of Contents for Walgreens WGNBPW-910

Page 1: ...AUTOMATIC WRIST Blood Pressure Monitor 5 Year Limited Warranty WGNBPW 910 Ver A El manual en espa ol empieza en la p gina 34...

Page 2: ...netic Compatibility EMC 26 Troubleshooting 28 Specifications 29 5 Year Limited Warranty 31 TABLE OF CONTENTS INTRODUCTORY INFORMATION Important Product Notices and Safety Instructions 3 About Blood Pr...

Page 3: ...s hemorrhage or temporary numbness to your wrist In general these symptoms should not last long However if you do not recover in time please seek advice from a medical professional Consult your physic...

Page 4: ...Hypertension refers to blood pressure that rises above its usual level when measured in a clinical setting such as a doctor s office BLOOD PRESSURE STANDARD The table below contains defined levels fo...

Page 5: ...through your artery Once the measurement is complete the cuff will automatically deflate Please note that any muscle movement during inflation will cause measurement error When measurement is complete...

Page 6: ...nformation Measurement Error Wrap the cuff correctly and keep wrist steady during measurement Measure again Air Circuit Abnormality Measure again Pressure Exceeding 300 mmHg Switch the unit off to cle...

Page 7: ...teries if The weak battery symbol appears on the display Nothing appears on the display when the power is switched on Note Date and time will need to be reset if batteries are removed or replaced Repl...

Page 8: ...jewelry etc prior to attaching the wrist monitor Clothing sleeves should be rolled up and the cuff should be wrapped around bare skin for correct measurements 2 Apply cuff to left wrist with palm fac...

Page 9: ...od pressure changes with every heartbeat and is in constant fluctuation throughout the day Blood pressure measurement can be affected by the position of the user his or her physiologic condition and o...

Page 10: ...flate the cuff to begin measurement START STOP 3 When the measurement is completed the cuff will deflate entirely and systolic pressure diastolic pressure and pulse will be shown simultaneously on the...

Page 11: ...nt with an irregular heartbeat was detected during measurement Usually this is not a cause for concern However if the symbol appears often we recommend you seek medical advice Please note that the dev...

Page 12: ...rements at the same time each day and use the same wrist for consistency Users should wait a minimum of 5 minutes before taking additional measurements More time may be necessary depending upon your p...

Page 13: ...ms with this device please contact HoMedics Consumer Relations contact information on warranty page Do not immerse the unit in water as this will result in damage to the unit 23 24 Do not subject the...

Page 14: ...ctromagnetic environments listed below and should only be used in such environments Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 RF energy is used only...

Page 15: ...tion from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broa...

Page 16: ...5 93 RH Storage Transportation Environment Temperature 13 F 158 F 25 C 70 C Humidity Less than 93 RH SPECIFICATIONS 30 Weight 0 20 lbs 91 7 g without batteries Wrist Circumference 5 3 7 7 13 5cm 19 5c...

Page 17: ...product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for w...

Page 18: ...MONITOR AUTOM TICO De presi n arterial para el brazo Garant a limitada por 5 a os WGNBPW 910 Ver A...

Page 19: ...i n de fecha y hora 47 Aplicaci n del brazalete 48 36 Postura correcta para la medici n 49 Procedimiento de medici n 50 ndice de categor a de riesgo 53 Detector de latidos card acos irregulares IHB 54...

Page 20: ...riosclerosis grave enfermedad renal grave o enfermedad vascular que pueda afectar la circulaci n 38 El uso excesivo puede provocar interferencia del flujo sangu neo lo que probablemente produzca sensa...

Page 21: ...n los Pulmones y la Sangre National Heart Lung and Blood Institute de los Institutos Nacionales de la Salud National Institutes of Health NIH de los Estados Unidos http www nhlbi nih gov health dci D...

Page 22: ...la que se encuentran sus resultados de medici n en la tabla del Instituto Nacional del Coraz n los Pulmones y la Sangre de los NIH y brinda una gu a si su lectura entra en una de las etapas que podr...

Page 23: ...r m s informaci n Error de medici n vuelva a colocarse el brazalete correctamente y mantenga la mu eca quieta durante la medici n Repita la medici n Irregularidad en el circuito de aire repita la medi...

Page 24: ...uevamente en su lugar 1 2 3 4 46 Reemplace las bater as si El s mbolo de bater a baja aparece en la pantalla No aparece nada en la pantalla cuando enciende el dispositivo Nota Si se extraen o sustituy...

Page 25: ...oj las alhajas que tenga en la mu eca etc antes de colocar el monitor para la mu eca Deber remangarse si tiene mangas largas y deber colocarse el brazalete sobre la piel desnuda para obtener una medic...

Page 26: ...arterial cambia con cada latido card aco y est en constante fluctuaci n durante todo el d a La medici n de la presi n arterial puede verse afectada por la posici n del usuario sus condiciones fisiol g...

Page 27: ...amente para comenzar la medici n START STOP 3 Cuando haya finalizado la medici n el brazalete se desinflar por completo y se mostrar n las lecturas de presi n sist lica presi n diast lica y pulso simu...

Page 28: ...arece un cono que lo indica Generalmente esto no es causa de preocupaci n Sin embargo si el s mbolo aparece con frecuencia recomendamos que busque asesoramiento m dico Tenga en cuenta que este disposi...

Page 29: ...d as a la misma hora y en la misma mu eca para establecer una coherencia Los usuarios deber n esperar un m nimo de 5 minutos antes de tomar otras mediciones Dependiendo de su fisiolog a es posible que...

Page 30: ...r del mismo Si tiene problemas con este dispositivo comun quese con Relaciones con el consumidor de HoMedics encontrar la informaci n de contacto en la p gina de la garant a No sumerja la unidad en ag...

Page 31: ...un tomacorriente de un circuito diferente al que est conectado el receptor Consulte con el distribuidor o con un t cnico experto en radio televisi n para obtener ayuda COMPATIBILIDAD ELECTROMAGN TICA...

Page 32: ...3 3 Vrms 150 kHz a 80 MHz 3 V m 80 MHz a 2 5 GHz No se aplica 10 V m No se deben acercar equipos de comunicaci n por RF port tiles o m viles a ninguna pieza del dispositivo incluidos los cables a una...

Page 33: ...nte la medici n Repita la medici n Sacudi la mu eca con el brazalete colocado Aparece el s mbolo de error E1 en la pantalla Irregularidad en el circuito de aire Repita la medici n Aparece el s mbolo d...

Page 34: ...8 10 Esta garant a se extiende nicamente a consumidores y no a distribuidores Para obtener servicio de garant a en su producto HoMedics p ngase en con tacto con un Representante de Relaciones con el...

Page 35: ...TO DISPONIBLES PARA LOS MATERIALES DEFECTUOSOS HOMEDICS SE RESERVA EL DERECHO DE REALIZAR SUSTITUCIONES EN VEZ DE REPARAR O CAMBIAR Esta garant a no se extiende a la compra de productos abiertos usado...

Reviews: