HoMedics spa REFLECTIVES M-8006 Instruction Manual And  Warranty Information Download Page 2

Give Your Face the Attention It Deserves

Thank you for purchasing the Spa Reflectives™ Illuminated Beauty
Mirror.  This, like the entire line of HoMedics products, is built with
high quality craftsmanship to ensure years of dependable use.

IMPORTANT SAFETY INSTRUCTIONS

THIS APPLIANCE IS INTENDED FOR HOUSEHOLD USE.
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY
WHEN CHILDREN ARE PRESENT, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:

WARNING—TO REDUCE THE RISK OF BURNS, 
ELECTROCUTION, FIRE OR INJURY TO PERSONS:

• Read all instructions before using.
• To protect against electrical hazards, do not use while bathing

or in the shower.

• Close supervision is necessary when any appliance is used by

or near children or by invalids.

• Unplug the appliance from outlet when not in use and before

cleaning.  

• Do not leave appliance unattended when it is plugged in.  
• Keep cord away from heated surfaces.

• Do not operate this appliance with a damaged cord or plug or if

the appliance malfunctions or has been dropped or damaged in
any manner.  Return appliance to a HoMedics Service Center for
examination, electrical or mechanical adjustment, or repair.  No
repairs should be attempted by the consumer.

• Use appliance only for intended use as described in this 

instruction book. The use of attachments not recommended or
sold by HoMedics may cause hazards.

• Do not use outdoors or operate where aerosol (spray) products

are being used, or where oxygen is being administered.

• Be sure mirror is not in a position where it can reflect sunlight;

reflected sunlight can cause fire.

• Do not use on a soft surface such as a bed, where openings may

be blocked.

• Turn Off and unplug cord before replacing light bulbs.
• Do not place or store appliance where it can fall or be pulled into

a tub or sink.

• Do not place in or drop into water or other liquid.
• If an appliance falls into water, unplug it immediately.  Do not

reach into the water.

• Bulb gets HOT quickly.  Touch only the base when turning on.
• DO NOT touch hot bulb, guard, or enclosure.
• Use on any 120 volt 60 hertz AC electric outlet (ordinary house

current).  Do not use it on any other electrical outlet.

SAVE THESE INSTRUCTIONS

SPECIAL WARNINGS

• DO NOT reach for an appliance that has fallen into water.  Unplug

it immediately.

• DO NOT place in or drop into water or other liquid.
• Use appliance on a sturdy or level surface.

To reduce the risk of electric shock, this appliance has a polar-
ized plug (one blade is wider than the other).  This plug will fit
in a polarized outlet only one way.  If the plug does not fit fully
in the outlet, reverse the plug.  If it still does not fit, contact a
qualified electrician to install the proper outlet.  Do not change
the plug in any way.

2

3

M-8006-B SP\ENG  11/22/04  1:49 PM  Page 3

Summary of Contents for spa REFLECTIVES M-8006

Page 1: ...uctos dañados por estas modificaciones no está cubierta bajo esta garantía HoMedics no será responsable de ningún tipo de daños incidentales consecuentes o especiales Todas las garantías implícitas incluyendo entre otras aquellas garantías implícitas de idoneidad y comerciabilidad están limitadas a la duración total de dos años a partir de la fecha de compra original Para obtener un servicio cubie...

Page 2: ...on book The use of attachments not recommended or sold by HoMedics may cause hazards Do not use outdoors or operate where aerosol spray products are being used or where oxygen is being administered Be sure mirror is not in a position where it can reflect sunlight reflected sunlight can cause fire Do not use on a soft surface such as a bed where openings may be blocked Turn Off and unplug cord befo...

Page 3: ...h control feature Touch the base of the mirror to activate Touch once for evening Low Touch a second time for office Medium Touch a third time for day High Touch a fourth time to turn off Note The mirror casing may be hot after prolonged use Be cautious when adjusting the mirror face To Replace Bulb Caution Before replacing the bulb always turn mirror off and allow it to cool for at least 5 minute...

Page 4: ... To Clean Always unplug before cleaning the mirror Never use liquids or abrasive cleaners to clean use only a damp cloth with a mild cleanser Clean the mirror with only a commercial glass cleaner or water Do not submerge the mirror or use excessive water while cleaning Do not plug mirror in until it is completely dry 6 PP MRBLB25 Replacement bulbs 4 bulbs 5 00 120v 25 Watt Type T Name Address City...

Page 5: ... under warranty HoMedics shall not be responsible for any type of incidental consequential or special damages All implied warranties including but not limited to those implied warranties of fitness and merchantability are limited in the total duration of two years from the original purchase date To obtain warranty service on your HoMedics product either hand deliver or mail the unit and your dated...

Page 6: ...dos por HoMedics puede ser peligroso NO lo haga funcionar afuera o donde se utilizan productos de rociado por aerosol o donde se está administrando oxígeno Asegúrese de que el espejo no esté en una posición donde pueda reflejar los rayos del sol el reflejo de los rayos solares puede ocasionar incendios NO lo utilice en una superficie blanda como una cama donde las aberturas puedan quedar bloqueada...

Page 7: ...función del control Illumi Touch Toque la base del espejo para activarlo Toque una vez para la noche bajo Toque una segunda vez para la oficina medio Toque una tercera vez para el día alto Toque una cuarta vez para apagarlo Nota La carcasa del espejo puede estar caliente después de un uso prolongado Sea cauteloso al ajustaor la cara de espejo Para cambiar la bombilla Precaución Antes de cambiar la...

Page 8: ...es abrasivos para limpiar utilice únicamente un paño húmedo con un producto de limpieza suave Limpie el espejo sólo con un limpiavidrios comercial o con agua No sumerja el espejo ni utilice agua en exceso mientras lo limpia NO enchufe el espejo hasta que no esté completamente seco Nombre Dirección Ciudad Estado Código postal Número de teléfono Dirección postal HoMedics Service Center Dept 168 3000...