13
Microbiological Performance
Bacteria: 99.9999% or 6 log reduction
Virus: 99.99% or 4 log reduction
Cyst: 99.95% or 3.5 log reduction
Intended for the supplemental purification of visually clear tap water only.
Substance
Infl uent Challenge
Concentration
Maximum
Permissable
Concentration
Average
Actual
Reduction
NSF 42 - Aesthetic Effects
Chlorine
- Taste and Odor
2 mg/L ± 10%
1 mg/L
98.9%
Zinc
10 mg/L ± 10%
5 mg/L
86.2%
NSF 53 - Health Effects
Benzene
0.015 mg/L ± 10%
0.005 mg/L
94.4%
Cadmium - pH 6.5
0.03 mg/L ± 10%
0.005 mg/L
91.8%
Cadmium - pH 8.5
0.03 mg/L ± 10%
0.005 mg/L
89.9%
Copper - pH 6.5
3 mg/L ± 10%
1.3 mg/L
89.7%
Copper - pH 8.5
3 mg/L ± 10%
1.3 mg/L
77.9%
Lindane*
0.002 mg/L ± 10%
0.0002 mg/L
99%
Mercury - pH 6.5
0.006 mg/L ± 10%
0.002 mg/L
96.2%
Mercury - pH 8.5
0.006 mg/L ± 10%
0.002 mg/L
94.3%
Tetrachloroethylene
0.015 mg/L ± 10%
0.005 mg/L
93.2%
Toluene
3 mg/L ± 10%
1 mg/L
99.4%
*Compliant for Lindane reduction requirements under NSF/ANSI
Standard 53 as tested by PACE Analytical Services, Inc.
Substance
Infl uent Challenge
Concentration
Maximum
Permissable
Concentration
Average
Actual
Reduction
NSF 53 (1988)
Lead pH 7.5**
0.150 mg/L ± 10%
0.020 mg/L
98.7%
**Meets the lead reduction requirements under NSF/ANSI Standard 53
(1988) as tested by PACE Analytical Services, Inc.
This system has been independently tested by PACE Analytical Services, Inc.
according to NSF/ANSI 53 (1988) for the reduction of lead.
Performance Data Sheet
HoMedics Restore™ Water System-Model: RWS-100
Replacement Filter-Model: RWS-1FL
Distributed by HoMedics, Inc.
3000 Pontiac Trail, Commerce Township, MI 48390
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI 42 and 53. Testing was performed
under standard laboratory conditions, actual performance may vary.
12