HoMedics AF-100 Instruction Manual And Warranty Download Page 4

6

7

Operating Instructions

Turning the Unit On

•  Take the air cleaner out of the box and remove the clear protective plastic bag.
•  Place the air cleaner on a firm level surface.
•  Before turning the air cleaner ON, you need to check that the filter is firmly in 

place and did not become loose during shipping.  

NOTE: This appliance has a polarized plug (one blade is wider than
the other). To reduce the risk of shock, this plug is intended to fit only
one way in a polarized outlet. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature. To do so could result in
an electric shock hazard.

Control Panel

NOTE: The Clean/Reset Filter Indicator MUST be pressed to reset the 

indicator after you have cleaned and replaced the filter.

Fig. 1

Clean Filter

2

hr    

4

hr    

6

hr    

8

hr    

10

hr    

12

hr 

Fig. 2

Clean Filte

r

2

hr    

4

hr    

6

hr    

8

hr    

10

hr    

12

hr 

Fig. 3

1. To check filter, open the front grill by 

pulling on the tabs on either side of 

the top of the grill plate. Fig. 1

2. Open the plate outward until the tabs 

at the bottom of the grill plate easily 

slide away from the unit. Fig. 2

 

3. The HEPA filter will be resting  

inside the unit. Make sure that the filter 

is firmly seated inside of the unit. Fig. 3

Clean Filter

2

hr    

4

hr    

6

hr    

8

hr    

10

hr    

12

hr 

Clean/Reset Filter  

Indicator Button

Fan Speed Indicator

Power ON/OFF Control

Timer Interval Selection

Timer Indicator

Fan Speed Selection  

(Low, Medium, High)

Remote 

Control

Summary of Contents for AF-100

Page 1: ... no sea aquél para el que fue diseñado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA C...

Page 2: ...ldren or invalids and whenever the air cleaner is left operating and unattended Always unplug the air cleaner when not in use Do not operate the air cleaner with a damaged cord or plug or after the air cleaner malfunctions or has been dropped or damaged in any manner Return to HoMedics Consumer Relations for examination electrical or mechanical adjustment or repair This air cleaner is not intended...

Page 3: ...Unit Height 18 5 This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model s CADR for Dust and the electrical energy it consumes or CADR Watt Control P...

Page 4: ...do so could result in an electric shock hazard Control Panel NOTE The Clean Reset Filter Indicator MUST be pressed to reset the indicator after you have cleaned and replaced the filter Fig 1 Clean Filter 2hr 4hr 6hr 8hr 10hr 12hr Fig 2 Clean Filter 2 hr 4 hr 6 hr 8 hr 10 hr 12 hr Fig 3 1 To check filter open the front grill by pulling on the tabs on either side of the top of the grill plate Fig 1 ...

Page 5: ...into the base of the unit Push the grill plate back into place until you hear a click sound indicating that the grill is firmly latched Fig 4 Plug the power cord into a standard AC outlet NOTE Unit will not operate unless filter and grill are properly installed 1 On Off and Fan Speed Settings To turn the air cleaner on press the ON OFF Control When the air cleaner is on the ON OFF Control will ill...

Page 6: ... 12 hr Fig 7 1 Open the front grill by pulling on the tabs on either side of the top of the grill plate Fig 5 2 Open the plate outward until the tabs at the bottom of the grill plate easily slide away from the unit Fig 6 3 Remove the HEPA filter from the main unit Fig 7 5 Place the clean HEPA filter back in the air cleaner in the direction indicated by the arrows on the sides of the filter Make su...

Page 7: ...nit will not operate Unit is not plugged in No power to unit Plug unit in Press the ON OFF button to turn the power on Check circuits fuses try a different outlet Reduced airflow or poor filtering The front grill may be blocked HEPA filter may be clogged Check to make sure nothing is blocking the front grill and air outlet Check and clean filter Replace the filter Excessive noise The unit is not l...

Page 8: ...roduct that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY...

Page 9: ...álidas y cuando el limpiador de aire se deje funcionando sin supervisión Desenchufe siempre el limpiador de aire cuando no lo esté usando No haga funcionar el limpiador de aire con un cable o un enchufe dañado o después de que el limpiador de aire no funcione adecuadamente se haya caído o dañado de cualquier manera Devuelva a Atención al consumidor de HoMedics para que lo examinen lo ajusten eléct...

Page 10: ...cto obtuvo la certificación ENERGY STAR cumpliendo estrictas pautas de eficiencia energética establecidas por US EPA US EPA no respalda ninguna declaración del fabricante sobre aire interior más saludable a partir del uso de este producto La eficiencia energética de este modelo calificado según ENERGY STAR se mide basándose en una relación entre la CADR tasa de suministro de aire limpio para el po...

Page 11: ...ca Panel de control NOTA El indicador de limpieza reajuste de filtro DEBE presionarse para reiniciar el indicador después de haber limpiado y cambiado el filtro Fig 1 Clean Filter 2hr 4hr 6hr 8hr 10hr 12hr Fig 2 Clean Filter 2 hr 4 hr 6 hr 8 hr 10 hr 12 hr Fig 3 1 Para controlar el filtro abra la rejilla delantera jalando de las lengüetas que se encuentran de cada lado de la parte superior de la p...

Page 12: ...no funcionará a menos que el filtro y la rejilla estén correctamente instalados 1 Encendido apagado y configuración de velocidad del ventilador Para encender el limpiador de aire presione el control ON OFF encendido apagado Cuando el limpiador de aire esté encendido el control ON OFF encendido apagado se iluminará y el limpiador de aire comenzará a funcionar en velocidad BAJA El limpiador de aire ...

Page 13: ...etas que se encuentran de cada lado de la parte superior de la placa de la rejilla Fig 5 2 Abra la placa hacia afuera hasta que las lengüetas de la parte inferior de la placa de la rejilla se deslicen fácilmente por la unidad Fig 6 3 Retire el filtro HEPA de la unidad principal Fig 7 5 Vuelva a colocar el filtro HEPA en el limpiador de aire en la dirección que indican las flechas en los lados del ...

Page 14: ...unidad no recibe energía eléctrica Enchufe la unidad Oprima el botón ON OFF para encenderla Revise los circuitos los fusibles pruebe otro tomacorriente Flujo de aire reducido o poca filtración La rejilla delantera puede estar obstruida Un filtro HEPA puede estar obstruido Verifique que no haya nada obstruyendo la rejilla delantera y la salida de aire Verifique y limpie el filtro Cambie el filtro R...

Reviews: