background image

1315-00

Page 2

60707-123

MODEL

HPS12000HE

Generator

Surge Watts*

12000

Continuous Watts*

10800

Volts 120/240

AMPs @ 240 Volts

45.0

AMPs @ 120 Volts

90.0

* Derate 10% for LP and 20% for NG
Engine

Honda

Size

688 cc/OHV

Model

GX630R VXE1

 Type -

See Engine Shroud For Type

Fuel Capacity-

15  gal

Fuel Consumption

Gasoline

1.67 gal/hr

LP

2.2 gal/hr

NG

200 cu ft/hr

Starting System

12V Electric

Stop System

Key

Complete Unit

Weight (dry)

396 LBS

Dimensions LxWxH

39.5 X 26 X 26

Fuel

Gasoline/LP/NG

Oil Type

SG SF/CC CD

Oil Weight (for general use)

10W -30

See engine manual for additional information

Oil Capacity

1.3  Quarts

Battery 12 Volt

Group U1/300CCA

INTENDED USES

These engine generator sets have been designed primarily

for portable use.  Both 120 and 240 Volt AC receptacles are

provided in the 'control panel' to plug in your loads (lights,

portable tools, and small appliances).  These units are dual

wound generators, therefore the 120 Volt loads must be

equally split with 1/2 of the rated capacity available on each

of the two 120 Volt circuits. See unit capabilities for further

explanation.
These portable units require large quantities of fresh air for

cooling of both the engine and the generator.  Fresh air is

drawn from both the engine end and the generator end and is

exhausted at the center of the unit.  For safety, long life and

adequate performance, these units should never be run in

small compartments or enclosed areas without positive fresh

air flow.

RESTRICTED USES

DO NOT 

remove from the cradle assembly.  Removal of the

generator from the cradle assembly may cause excessive

vibration and damage to the engine generator set.

DO NOT

 install and operate these portable generators in a

small compartment., i.e. generator compartment of vehicles,

motor homes or travel trailers.  These compartments will not

allow enough free flow fresh air to reach the  engine

generator set for cooling and will cause the unit to overheat,

damaging both the engine and the generator.  Small

compartments will also develop hot spots where there is very

little air flow and may cause a fire.

DO NOT

 attempt to operate at 50 cycles.  These units are

designed and governed to operate at 60 Cycles only.

SPECIFICATIONS

MODEL

CSAHPS6000HE

Generator

Surge Watts*

6000

Continuous Watts*

5500

Volts

120/240

AMPs @ 240 Volts

22.9

AMPs @ 120 Volts

45.8

* Derate 10% for LP and 20% for NG
Engine

Honda

Size

337cc/OHV

Model

GX340RT1VWE2

Type -

See Engine Shroud For Type

Fuel Capacity-

4.5 gal

Fuel Consumption

Gasoline

1.0 gal/hr

LP

1.6 gal/hr

NG

160 cu ft/hr

Starting System

Recoil/12V Electric

Stop System

Key

Complete Unit

Weight (dry)

212 LBS

Dimensions LxWxH

30 X 22 X 22

Owner Must Provide

Fuel

Gasoline/LP/NG

Oil Type

SG SF/CC CD

Oil Weight (for general use)

10W -30

See engine manual for additional information

Oil Capacity

1.2 Quarts

Battery 12 Volt

U1/275CCA

MODEL

CSAHPS9000E

Generator

Surge Watts*

9000

Continuous Watts*

8000

Volts 120/240

AMPs @ 240 Volts

33.3

AMPs @ 120 Volts

66.7

* Derate 10% for LP and 20% for NG
Engine

Briggs & Stratton

Size

480cc/OHV

Model

305447

 Type -

0133-G2

Fuel Capacity-

4.5 gal

Fuel Consumption

Gasoline

1.3 gal/hr

LP

1.9 gal/hr

NG

180 cu ft/hr

Starting System

Recoil/12V Electric

Stop System

Key

Complete Unit

Weight (dry)

274 LBS

Dimensions LxWxH

32 X 22 X 22

Fuel

Gasoline/LP/NG

Oil Type

SE SG SF

Oil Weight

See Engine Manual

specific information

Oil Capacity

1.75  Quarts

Battery 12 Volt

U1/275CCA

Summary of Contents for HPS12000HE/E

Page 1: ...INSTALLATION OPERATION and MAINTENANCE INSTRUCTIONS TRI FUEL PORTABLE GENERATORS OWNERS MANUAL HPS9000VE MODELS HPS6000HE H HPS9000VE D HPS12000HE E HPS6000HE HPS12000HE ...

Page 2: ...L NUMBER HERE No other HOME POWER generator has the same serial number as yours It is important that you record the number and other vital information here If you should ever need to contact us on this unit it will help us to respond to your needs faster MODEL______________________________________ SERIAL NUMBER _____________________________ PURCHASEDATE_____________________________ DEALER_________...

Page 3: ...fuels always present a hazard of possible explosion and or fire a Do not refuel when the engine is running or hot Allow the engine to cool at least two minutes before refueling b Keep fuel containers out of reach of children c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropr...

Page 4: ... damage to the engine generator set DO NOT install and operate these portable generators in a small compartment i e generator compartment of vehicles motor homes or travel trailers These compartments will not allow enough free flow fresh air to reach the engine generator set for cooling and will cause the unit to overheat damaging both the engine and the generator Small compartments will also deve...

Page 5: ...minutes to insure that the unit you have received is the correct model and review the specification pages in this manual to insure that this unit fits your job requirements 3 After removing the engine generator from the carton locate and remove the shipping strap attached to the generator shock mount See attached tag for removal instructions UNIT CAPABILITIES Generator Connections The diagram belo...

Page 6: ...thout a battery on gasoline only Installation and servicing of batteries must be performed or supervised only by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When installing or replacing batteries use the proper group size starting battery The battery should be a Maintenance Free lead acid design Deep cycle batteries will not wor...

Page 7: ... the engine the engine switch will remain in the ON position GASOLINE FUEL When using gasoline always use a good grade of unleaded fuel Leaded gasoline may be used if unleaded is not available Gasoline containing alcohol such as gasohol is not recommended However if gasoline with Ethanol is used it must not contain more than 10 percent Ethanol and must be removed from the engine during storage DO ...

Page 8: ... optional fuel solenoid DANGER PERSONAL INJURY Do not use galvanized pipe in the fuel line runs The galvanized coating will become eroded and flake off causing possible obstruction or damage to the regulator or fuel valve The obstruction could cause an inoperative engine or an explosive fuel leak Size of pipe required for generators operating on natural gas LP gas Length of Fuel Line Fuel Line Siz...

Page 9: ... the demand regulator 4 Reinstall the plastic plug in the regulator 5 Check to be sure the gasoline fuel valve is off 6 Fill the gasoline fuel tank 7 Turn on the gasoline fuel valve 8 Start the engine Optional Dolly Kit HPS9000 HPS6000 An optional dolly kit is available for these engine generator sets The dolly kit comes with instructions and parts list After installing the dolly kit file the inst...

Page 10: ...l with fresh oil d Remove the spark plug pour approximately 1 2 ounce 15 cc of engine oil into the cylinder and crank slowly to distribute oil Replace spark plug e Clean dirt and chaff from cylinder cylinder head fins blower housing rotating screen and muffler areas f Store in a clean and dry area OPERATING SPEED The engine generator must be run at the correct speed in order to produce the proper ...

Page 11: ...d local codes and regulations Check with local authorities before proceeding These generators come equipped with a 4 wire 120 240 volt receptacle designed to power both 120 and 240 volt loads There are 2 hots a neutral and a ground wire connection in the 4 wire 120 240 volt receptacle L14 30R This receptacle is protected by a double pole circuit breaker rated for generator output Below is a table ...

Page 12: ...r every 25 hours whichever occurs first Service more often if necessary Clean by tapping gently on flat surface If very dirty replace the cartridge using only original equipment parts available at any engine service center Do not use petroleum solvents such as kerosene to attempt to clean the cartridge They may cause deterioration of the cartridge DO NOT OIL CARTRIDGE DO NOT USE PRESSURIZED AIR TO...

Page 13: ...be removed every 50 hours for cleaning and inspection Replace if damaged TROUBLESHOOTING HINTS PROBLEM SYMPTOMS POSSIBLE CAUSES Won t Start Low Oil Level Fouled spark plug Out of fuel Stop switch in stop position Wrong fuel pressure Fuel is shut off Runs rough Wrong fuel pressure Not enough fuel volume Fuel mixture not properly adjusted Gasoline carburetor gummed up Fuel filter plugged ___________...

Page 14: ...1315 00 Page 12 60707 123 DATE ITEM WORK PERFORMED ...

Page 15: ...enter Minnesota THERE IS NO OTHER EXPRESS WARRANTY To the extent permitted by law any and all warranties including those of merchantability and fitness for a particu lar purpose are limited to 12 months or 1000 hours which ever accurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied w...

Page 16: ...225 S Cordova Ave LeCenter Mn 56057 60707 123 1315 00 ...

Reviews: