background image

Page 3

• Combustible material should not be within 72 inches of the top of the unit, or within 48 inches
around the entire unit. 
• Keep the appliance area clear and free from combustible material, gasoline and other flammable
vapors and liquids.
• If the flame goes out while burning, turn the gas valve off. Wait 5 minutes before repeating the initial
lighting procedure. Once you have a flame started, hold down the control knob for 1 minute.
• Do not add water into the unit.
• Do not operate unit if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and replace any part of the control system and any gas
control that has been under water.
• Do not disconnect any part while unit is in use.
• Do not store a spare propane tank on or near this unit.
• If the heating unit is indoors, detach the propane tank and leave outdoors.
• Do not operate on a boat or vehicle. This unit must be used on a flat surface and outdoors ONLY.
• Always remove protective cover before operating (if applicable).
• Do not set the protective cover over the unit until it is turned off and completely cooled down.
• Check for leaks after not using the unit for long periods of time.

• Children should never operate this unit. Children must be supervised while near this unit.

• Keep gas tank at least 5 feet away from unit when lit. (if external tank)
• The maximum gas supply pressure is 250psi.

• All installation and repair should be done by a qualified professional. This unit should be
inspected annually and cleaned regularly.

• Inspect all elements of this heating unit before each use. If there is damage, the burner must be
replaced.  
• Keep the hose out from any pathways to eliminate any accidental damage. (if external tank)
• Be aware of the hazards of high temperatures and stay away from the unit to avoid any burns or
injury. 
• The gas supply tank should be constructed and marked with the specifications for the LP gas tanks
of the U.S. Department of Transportation or the National Standard of Canada CAN/CSA-B339, LP gas 
tanks, spheres and tubes for Transportation of Dangerous Goods; and Commission. 
• The LP gas tank must have a listed overfilling prevention device and a QCCI or Type I, (CGA810) LP
gas tank connection.

• This heating appliance should not be used on plastic or artificial wood 

decks.

• Children and adults should be alerted to the hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
• Young children should be carefully supervised when they are in the area of the appliance.
• Clothing or other flammable materials should not be hung from the appliance or placed on or
near the appliance.
• Any guard or other protective device removed for servicing the appliance shall be replaced
prior to operating the appliance.
• Installation and repair should be done by a qualified service person. The appliance should be
inspected before use and at least annually by a qualified service person. More frequent cleaning 
may be required as necessary. It is imperative that the control compartment, burners and 
circulating airways of the appliance are kept clean.

 

IF APPLICABLE:

• Allow heating item to cool completely before placing on lid.

• DO NOT use heating item while lid is installed. Always remove the lid while heating item is in use.

 

•   Propane cylinder required(not included).

Summary of Contents for A302004100

Page 1: ...stment alteration service or maintenance can cause injury or property damage Read the owner s manual thoroughly before installing or servicing this equipment If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Save these instructions for future use If you are assembling this unit for someone else give this...

Page 2: ...t use a flame to check for gas leaks The max inlet supply pressure max Gas supply 11 in w c 2 74kPa Use LP propane tanks with the following dimensions diameter 12 in height 18 in capacity 20 lbs You must use a propane tank that has a collar to protect the gas valve DO NOT fill tank over 80 percent full The tank system must be set up for vapor withdrawal Discontinue use if any part of the propane t...

Page 3: ...e the burner must be replaced Keep the hose out from any pathways to eliminate any accidental damage if external tank Be aware of the hazards of high temperatures and stay away from the unit to avoid any burns or injury The gas supply tank should be constructed and marked with the specifications for the LP gas tanks of the U S Department of Transportation or the National Standard of Canada CAN CSA...

Page 4: ...ent of the burner or any other parts calls the manufactuer NOTE You must follow all steps to properly assemble this heating item Make sure the gas valve is turned OFF before assembling Do NOT attempt to assemble without proper tools SAFETY INFORMATION Min Clearance 48 in 121 9 cm Min Clearance 48 in 121 9 cm Min Clearance 48 in 121 9 cm Min Clearance 48 in 121 9 cm Combustible materials should not...

Page 5: ...E Guard preassembled Burner preassembled Page 5 Item Description Qty A Lava Rocks 2 boxes B 1 C Body 1 D Tank Holder 1 1 F Control Knob preassembled 1 G Electronic Igniter preassembled 1 CONTENTS ...

Page 6: ...e tank into the tank holder CYLINDER VALVE PRESSURE RELIEF VALVE BLEED OFF VALVE BLACK COUPLING NUT REGULATOR turn clockwise to connect turn clockwise to reseal 3 Turn the cylinder valve on the tank clockwise to close the propane tank Attach the preassembled regulator from the body C to the cylinder valve by turning the regulator coupling nut clockwise Make sure it is fastened securely and tighten...

Page 7: ...luded into the battery slot Make sure the positive side of the battery faces outwards Screw the igniter cap G over the battery tightly 5 Pour the box of lava rocks A into the fire table body C WARNING To ensure proper function the guard I on this burner B should be free of lava rocks at all times G electronic ...

Page 8: ...uishing flame prior to placing a lid if applicable or protective cover on heating item 1 Make sure the control knob F is in the off position Slowly open the valve on the propane gas tank by turning the knob counterclockwise 2 Push and hold in the electronic igniter G to create sparks within the electrode continue to hold 3 Push in the control knob F and turn to the low position Keep holding down t...

Page 9: ...g on a product Do not slide products across the product surface to avoid permanent scratching and cleaning the product surface Product Surface Care tabletop and dry completely to avoid water spots Regularly cleaning the product surface will Clean any spills immediately to prevent permanent product surface staining or damage Clean your product surface with a soft clean cloth or sponge Mix a solutio...

Page 10: ...e is kinked Straighten hose of all bends or kinks No gas flow Check that the gas tank isn t empty Excess flow safety valve has been activated Turn the control knob to the off posi tion Close the tank valve and disconnect propane gas tank Turn the control knob to high wait 1 minute Turn the control knob back to the off position Recon nect propane gas tank Light the fire unit as indicated in the To ...