1
Safety Rules - Read and Save These Instructions
To reduce the risk of electric shock, insure electricity has been turned off
at the circuit breaker or fuse box before beginning.
All wiring must be in accordance with the National Electrical Code
“ANSI/NFPA 70-1999”
and local electrical codes. Electrical installation
should be performed by a qualified licensed electrician.
A all-pole disconnection that provide full disconnection under
overvoltage category III from the supply mains incorporated in the fixed
wiring is to be provided during installed.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
After installed, need a set of supply leads accommodated in a suitable
compartment.
WARNING:
To reduce the risk of electrical shock or fire, do not use this
fan with any solid-state fan speed control device. It will permanently
damage the electronic circuitry.
CAUTION:
To reduce the risk of personal injury, use only the screws
provided with the outlet box.
The outlet box and support structure must be securely mounted and
capable of reliably supporting a minimum of 35 lbs (15.9 kg) or less. Use
only UL-listed outlet boxes marked
“FOR FAN SUPPORT”
.
The fan must be mounted with a minimum of 10 ft (3.05m) clearance
from the trailing edge of the blades to the floor.
Avoid placing objects in the path of the blades.
To avoid personal injury or damage to the fan and other items, be
cautious when working around or cleaning the fan.
Do not use water or detergents when cleaning the fan or fan blades. A dry
dust cloth or lightly dampened cloth will be suitable for most cleaning.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
TO REDUCE THE RISK OF PERSONALL INJURY, DO NOT BEND THE BLADE
ARMS (ALSO REFERRED TO AS FLANGES), WHEN INSTALLING THE
BRACKETS, BALANCING THE BLADES OR CLEANING THE FAN. DO NOT
INSERT FOREIGN OBJECTS IN – BETWEEN ROTATING FAN BLADES.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,
MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT
WITH THE SCREWS PROVIDED WITH THE OUTLET BOX.
WARNING
After making electrical connections, spliced conductors should be turned
upward and pushed carefully up into outlet box. The wires should be
spread apart with the grounded conductor and the equipment-grounding
conductor on one side of the outlet box and ungrounded conductor on the
other side of the outlet box.
All set screws must be checked and retightened where necessary before
installation.
The appliance is not to be used by persons (including children) with reduced
physical, sensory or metal capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Instructions for the use of the apparatus according with NOM-024-SCFI, are
provided with the apparatus.