WARNING:
Perform all leak tests outdoors.
Extinguish all open flames.
NEVER leak test when smoking.
Do not use the fire pit until all connections
have been leak tested and confirmed no leakage.
HOMEDEPOT.COM/HOMEDECORATORS
Please contact 1-800-986-3460 for further assistance.
Operation(continued)
CAUTION:
The gas supply must be turned off at the LP gas supply cylinder when this appliance is not in use.
Leak Check
Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
Apply several drops of solution where hose attaches to regulator.
Apply several drops of solution where regulator connects to cylinder.
Make sure all fire pit and light valves are OFF.
Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
Turn cylinder valve OFF.
Regulator / Cylinder
connection
Hose / Regulator
connection
11
□
□
□
□
□
□
If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles
continue appearing, the hose should be returned to the place of purchase.
If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be
returned to cylinder’s place of purchase.
If NO bubbles appear at any connection, the connections are secure.
□□
□
□
Immediately remove any spot or stain.
To clean, wash with a mild soap, rinse with water and let air dry.
Do not use strong solvents or bleach as they may damage the surface.
Use an outdoor cover to extend the life of the item.
Care and Maintenance
CAUTION:
Surfaces of fire pit can remain extremely hot for a period after use. Allow 45 minutes to cool down before touching or
moving the fire pit.
NOTE:
Whenever gas connections are loosened or removed, you must perform a complete leak test.