background image

Installation   and   Operation   Manual         

 

-­‐   7   -­‐   

INSTALLATION – Fitting of Integrated Rangehood 

Fit 150mm duct spigot (pictured below) with the four 8mm screws provided over the 
rectangular hole located at the top rear of the integrated rangehood.  Fit 150mm flexible 
ducting (pictured below), supplied, to the ducting spigot, Using one of the nylon ties, 
supplied, secure the ducting to the duct spigot.  

A hole or cutout needs to be made in the centre rear of the removable shelf positioned 
above the integrated rangehood for the ducting to go through. 

 

 

 

 

 

 

Mount the Integrated Rangehood onto the two tabs on the mounting bracket into the two 
matching slots located at the rear of the rangehood. (Fig. 4)  

 

 

 

 

 

 

 

 

 

 

 

 

Mounting bracket

Integrated Rangehood

Removable shelf 

(Cannot be permanently 

fixed if the need for 

servicing is required)

Fig. 4

Slots to mount to 

tabs of mounting 

bracket

Mounting bracket

Integrated Rangehood

Removable shelf 

(Cannot be permanently 

fixed if the need for 

servicing is required)

Fig. 4

Slots to mount to 

tabs of mounting 

bracket

150mm duct spigot

150mm flexible ducting

Summary of Contents for IRI6SE1

Page 1: ...Installation and Operation Manual 1 MODEL IRI6SE1 600mm Integrated Rangehood Manual Installation and Operation...

Page 2: ...s of reliable service Please ensure this manual is read carefully before installation and use Keep this manual in a safe and accessible location should future reference be required Regards Home Applia...

Page 3: ...Rangehood should be unplugged before any maintenance or cleaning is carried out This Integrated Canopy Rangehood cannot be installed in an external environment The Grease Filters should be cleaned at...

Page 4: ...Installation and Operation Manual 4 DIMENSIONS...

Page 5: ...suited for a 600mm cupboard and the IRI9WE3 IRI9SE1 is suited for a 900mm cupboard Installation of the IRI9WE3 IRI9SE1 Integrated rangehood in an overhead cupboard Height Requirement The minimum inst...

Page 6: ...rom base of rangehood to the mid point of the centre screw hole on the mounting bracket This may vary slightly to the dimensions mentioned in Fig 3 and should be the one you use to ensure the base of...

Page 7: ...e rear of the removable shelf positioned above the integrated rangehood for the ducting to go through Mount the Integrated Rangehood onto the two tabs on the mounting bracket into the two matching slo...

Page 8: ...od The shelf above the top of the rangehood needs to removable should the need for servicing be required at a later date The shelf needs to be located no less than 400mm above the top of the rangehood...

Page 9: ...rhead cupboard is open Fig 6 Carbon filters may be required to reduce any fumes or smells being re directed back into the kitchen environment Call 1800 805 300 to order carbon filters if required Carb...

Page 10: ...gehood depress either the Low Mid or High electronic push buttons When ON the back lit push button will glow blue to indicate your selection You may wish to start on Low prior to cooking commencing an...

Page 11: ...r Please follow the following steps to conduct this procedure Halogen bulb type 20W 12V G4 NOTE Replacement of halogen light bulbs are not covered under the 2 years parts and labour warranty Step 1 Re...

Page 12: ...of the Rangehood As cooking can create a great deal of grease we recommend that the rangehood body and motor housing area be cleaned every 3 months Ensure that non caustic abrasive detergents or harsh...