11
No person carrying out work in relation to a refrigeration system which
involves exposing any pipe work that contains or has contained flammable
refrigerant shall use any sources of ignition in such a manner that it may
lead to the risk of fire or explosion. All possible ignition sources, including
cigarette smoking, should be kept sufficiently far away from the site of
installation, repairing, removing and disposal, during which flammable
refrigerant can possibly be released to the surrounding space. Prior to
work taking place, the area around the equipment is to be surveyed to
make sure that there are no flammable hazards or ignition ris
ks. “No
Smoking”
signs shall be displayed.
2.2.7
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work. A degree of
ventilation shall continue during the period that the work is carried out.
The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
2.2.8
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt consult
the
manufacturer’s
technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants:
–
The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
–
The ventilation machinery and outlets are operating adequately and are
not obstructed;
–
If an indirect refrigerating circuit is being used, the secondary circuit
shall be checked for the presence of refrigerant;
–
Marking to the equipment continues to be visible and legible. Markings
and signs that are illegible shall be corrected;
Summary of Contents for 823- 005V92
Page 20: ...20 5 1 CONTROL PANEL AND DISPLAY 5 OPERATION...
Page 21: ...21 5 2 REMOTE CONTROL...
Page 31: ...823 005V70 823 005V71 823 005V72 823 005V90 823 005V91 823 005V92...
Page 47: ......
Page 73: ...69 5 1 PANNEAU DE COMMANDE ET AFFICHAGE 5 OP RATION...
Page 99: ...95 5 OPERACI N 5 1 PANEL DE CONTROL Y PANTALLA...
Page 127: ...123 2 UTILIZARE 2 1PANOUL DE CONTROL I AFI AJUL...
Page 128: ...124 1 2 TELECOMANDA...
Page 131: ...127 Ap sa i butonul VITEZ n mod repetat pentru a selecta viteza dorit a ventilatorului...
Page 141: ...137...
Page 142: ...138...