2. Safety Warnings 

2.1. General Instructions 
Signs used to mark instructions in this manual 

Safety instructions in these operating instructions, 

which, if not observed, could cause a danger for persons 
are marked with the general symbol in accordance with 
DIN 4844-W 9. 

Warnings against electrical voltage are marked with 

the safety symbol in accordance with DIN 4844-W 8. 
 
2.2. General Safety Precautions 
General regulations and guidelines not mentoined in the  
safety warnings retain their validity. 

These operating instructions contain basic instruc-

tions, which have to be adhered to during installation, op-
eration and maintenance. These operating instructions 
must be read from mechanic and the operator before in-
stallation and operation of the pump and have to be kept 
available at the operating place of the machine/unit at all 
times. Persons who are not familiar with the operating in-
structions shall not use this product. 
Children and adolescents under age 16 shall not use 
the pump and must keep away from the machine/unit  
while it is operational.
 

The working area has to be closed off expediently 

and must adhere to local workplace regulations. 

Always use personal safety equipment such as safety 

boots, rubber gloves, safety glasses and helmet. 

Make sure that the emergency exit from the work-

place is not barricaded. 

To prevent suffocation and poisoning caused by ven-

omous gases, make sure that enough oxygen exists at 
the workplace. 

If you have to work with welding tools or electric tools, 

make sure that there is no explosion hazard. 

Immediately after repair or maintenance work, all 

safety and protection equipment must be reinstalled and 
placed in function again. 

The operator of the pump is responsible for third par-

ties within the work area. 

Never put a hand or finger into suction inlet or dis-

charge of the pump while the impeller is rotating. 

Persons are not permitted to stay in the pumping me-

dium during operation of the pump. 

All other rules and regulations and local codes cover-

ing health and safety must be observed. In accordance 
with product liability law, we point out that we shall not be 
liable for damages caused by the pump due to non-
observance of the instructions and guidelines set forth in 
the operating instructions. The same product liability are 
valid for accessories. 
 

3. Applications and Technical Description 

3.1. Applications 

If the pump is used for cleaning or maintenance of 

swimming pools, make sure that no persons stay in the 
swimming pool during operation of the pump and that the 
pump is reliable by a 30 mA earth leakage circuit breaker. 

TCV, TCM pumps are designed for pumping drainage  
water or waste water, containing sludge or soft solids.  
The pumps are used for installations in public and private 
sector. 
The pumps must not be used for pumping of liquids con-
taining great quantities of abrasive solids, like sand or 
stones. Before the pumping of chemically aggressive liq-
uids, the resistance of the pump materials must be 
checked. 
The pumps may be used for both temporary or permanent 
installation. The installation can be free-standing on a 
base-stand or by means of an auto-coupling guide rail  
system (available as accessory). 

3.2. Technical Data 

Discharge  
TCV 4..., TCV 5... 

BSP 2“ F  

TCV 6..., TCM 6 

BSP 2 ½ “ F 

Voltage  
1Ph-Motor (Model W) 

230 V 

3Ph-Motor (Model D) 

400 V 

Speed 2900 

rpm 

Insulation class 

Motor protection 

IP 68 

Cable 10 

Cable type 

H 07RN-F... 

Noise level during operation, 1,60 m from the 
ground 

 70d(B)A 

 
3.3. Operating Conditions 
Maximum liquid temperature:
 35°C, short term up to 
60°C. 
Density of pumped liquid: max. 1100 kg/m

3

 

Ph-value of pumped liquid: 5 up to 11. 
Level of pumped liquid: The lowest level must always 
be above the top of the pump housing (volute). 
Operation: The motors are designed for continuous op-
eration (S1) with fully submerged motor, maximum 15 
starts per hour. Our standard warranty and maintenance 
regulations refer to intermittent operation. For reduced 
warranty periods and service intervals due to continuous 
operating conditions please contact our service 
department. 

3.4. Explosive Enviroments 

For operation of the pumps in explosive enviroments 

only models with explosion-proof motors (s. HOMA prod-
uct range) must be used. 

For each individual installation the explosion classifi-

cation (Ex-class) of the pump must be approved by the 
local authorities. 
 

4. Warranty 

Our warranty only covers pumps which are installed and 
operated in accordance with these installation and opera-
tion instructions and accepted codes of good practice and 
being used for the applications mentoined in these in-
structions. 
 

5. Transport and Storage 

Never use the cable or the discharge hose/pipe to lift, 

lower, transport or attach the pump. Always use the han-
dle or a rope or a chain attached to the handle. 

The pump may be transported and stored in vertical 

or horizontal position. Make sure that it cannot roll or fall 
over. For longer periods of storage, the pump should be 
protected against moisture, frost or heat. 

Summary of Contents for TCM 6 Series

Page 1: ...Montage und Bedienungsanleitung Installation and Operation Instruction Manual 01 2005 Baureihe Series TCV TCM...

Page 2: ...2 Inhalt Contents Seite 3 Page 9 Seite 15 Page 15 DEUTSCH ENGLISH Bauma e Dimensions...

Page 3: ...die Pumpentypen TCV TCM aufgrund Ihrer Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderun gen der EG Ma...

Page 4: ...eise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten die gleichen Be stimmungen 3 Einsatz und Technische Beschreibung 3 1 Einsatz der Pump...

Page 5: ...icklungen im Stern geschaltet f r eine Netzspannung von 400 V 3Ph Die Kabelenden U V W ber den Motorschutzschalter mit den Netzanschlussklemmen L1 L2 L3 zu verbinden 6 3 Temperaturf hler Die 1 Ph Moto...

Page 6: ...tandsdifferenz zwi schen Ein und Ausschaltpunkt l sst sich individuell be stimmen F r eine einwandfreie Funktion beachten Sie bitte die nachstehenden Hinweise Die Befestigungspunkte sowie die L nge de...

Page 7: ...zu entsorgen lf ll mengen siehe Tabelle auf Seite Wartungsvertrag Zur regelm igen fachm nnischen Durchf hrung aller notwendigen Wartungs und Kontrollarbeiten empfehlen wir den Abschluss eines Wartungs...

Page 8: ...d erfragen Sie bitte bei unserem 0 22 47 70 20 Kundendienst unter der Hotline f r Notf lle Telefonnummer 0 22 47 70 20 0 22 47 70 23 31 Auf das im beiliegenden Garantieschein beschriebene Produkt gew...

Page 9: ...bH Industriestrasse 1 D 53819 Neunkirchen Seelscheid hereby declare that in respect to their design and construction the following pump types in the form in which they are marketed by us conform to th...

Page 10: ...s used for cleaning or maintenance of swimming pools make sure that no persons stay in the swimming pool during operation of the pump and that the pump is reliable by a 30 mA earth leakage circuit bre...

Page 11: ...the direction of rotation is not cor rect With smaller pumps the direction of rotation may be checked by watching the start jek Put the pump vertical on the ground and lift one edge Start the motor V...

Page 12: ...ol box to the required mode of operation 9 Maintenance and Repair In case of a defect of the pump a repair shall be car ried out only by the manufacturer or through an author ized workshop Modificatio...

Page 13: ...terial defects or production defects Costs for removal and installation of the complained product at the installation place costs for the ride of the mechanicians to the location and from the installa...

Page 14: ...ichnung des Ersatzteiles 1 2 3 4 Ben tigte Menge 1 2 3 4 Lieferanschrift Unterschrift Firmenstempel 13 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47...

Page 15: ...in mm Typ type A B D E F G TCV 4 TCV 5 R 2 AG BSP 2 M 180 221 95 370 180 TCV 6 TCM 6 R 2 AG BSP 2 M 220 260 125 440 210 Schachtinstallation mit Kupplungssystem Submerged Installation with auto couplin...