Homa H 842 Installation And Operation Instruction Manual Download Page 8

 

2. Safety Warnings 

2.1. General Instructions 
Signs used to mark instructions in this manual 

Safety instructions in these operating instructions, 

which, if not observed, could cause a danger for persons 
are marked with the general symbol in accordance with 
DIN 4844-W 9. 

Warnings against electrical voltage are marked with 

the safety symbol in accordance with DIN 4844-W 8. 
 
2.2. General Safety Precautions 
General regulations and guidelines not mentoined in the  
safety warnings retain their validity. 

These operating instructions contain basic instruc-

tions, which have to be adhered to during installation, 
operation and maintenance. These operating instructions 
must be read from mechanic and the operator before 
installation and operation of the pump and have to be 
kept available at the operating place of the machine/unit 
at all times. Persons who are not familiar with the operat-
ing instructions shall not use this product. 
Children and adolescents under age 16 shall not use 
the pump and must keep away from the machine/unit  
while it is operational.
 

The working area has to be closed off expediently 

and must adhere to local workplace regulations. 

Make sure that the emergency exit from the work-

place is not barricaded. 

To prevent suffocation and poisoning caused by 

venomous gases, make sure that enough oxygen exists 
at the workplace. 

If you have to work with welding tools or electric tools, 

make sure that there is no explosion hazard. 

Immediately after repair or maintenance work, all 

safety and protection equipment must be reinstalled and 
placed in function again. 

The operator of the pump is responsible for third 

parties within the work area. 

Never put a hand or finger into suction inlet or dis-

charge of the pump while the impeller is rotating. 

Persons are not permitted to stay in the pumping 

medium during operation of the pump. 

All other rules and regulations and local codes cover-

ing health and safety must be observed. In accordance 
with product liability law, we point out that we shall not be 
liable for damages caused by the pump due to non-
observance of the instructions and guidelines set forth in 
the operating instructions. The same product liability are 
valid for accessories. 
 

3. Applications and Technical Description 

3.1. Applications 

If the pump is used for cleaning or maintenance of 

swimming pools, make sure that no persons stay in the 
swimming pool during operation of the pump and that the 
pump is reliable by a 30 mA earth leakage circuit breaker. 
H 800 series pumps are designed for pumping clear wa-
ter from tanks or cisterns.  

HOMA deepwell submersible pumps are suitable for 
pumping clear water with high pressure, even from close 
boreholes, wells and pits. They are used for domestic 
water supply, irrigation, garden watering from cisterns or 
similiar, in fountain displays, watering place, heat pumps, 
ground water drainage and so on. In combination with the 
electronic control panel HPS 2 or with a pressure tank, 
pressure switch and an electrical control panel the pumps 
can operate automatically (see accessories).  
 
Horizontal or vertical installation are possible, with vertical 
installation also direct hanging of the pump up at the 
discharge pipe. 
 
3.2. Technical Data 

Discharge 
H 842 - H 844 
H 846 – H 847 
H 862 – H 863 

 
1¼“ 
2“ 
3“ 

Solid size max. 

0,1 mm 

Voltage 230 

Speed 2900 

rpm 

Insulation class 

Motor Protection 

IP 68 

Cable 20 

 
3.3. Operating Conditions 
Maximum liquid temperature: max. 35°C 
Maximum quantity of sand in the medium: 40 g/m³ 
 
3.4. Explosive Enviroments
 

The pumps must not be used in explosive invi-

roments. 
 

4. Warranty 

Our warranty only covers pumps which are installed and 
operated in accordance with these installation and opera-
tion instructions and accepted codes of good practice and 
being used for the applications mentioned in these in-
structions. 
 

5. Transport and Storage 

Never use the cable or the discharge hose/pipe to lift, 

lower, transport or attach the pump. Always use the han-
dle or a rope or a chain attached to the handle. 

The pump may be transported and stored in vertical 

or horizontal position. Make sure that it cannot roll or fall 
over. For longer periods of storage, the pump should be 
protected against moisture, frost or heat. 
 

6. Electrical Connection 

Before operation, an expert check must secure that 

the required electrical protection measures exist. The 
connection to ground, earthing, isolating transformer, fault 
current breaker or fault voltags circuit must correspond to 
the guidelines set forth by the responsible power plant. 

The voltage required in the technical data sheet 

must correspond to the existing line voltage. 

Submersible pumps used outside of buildings must  

have a cable with a minimum length of 10m. 

Summary of Contents for H 842

Page 1: ...Montage und Bedienungsanleitung Installation and Operation Instruction Manual 01 2005 Hochdruck Tauchmotorpumpen Deepwell Submersible Pumps H 842 H 844 H 846 H 847 H 862 H 863...

Page 2: ...schl gigen grundlegenden Sicherheits und Gesundheitsanforderun gen der EG Maschinenrichtlinien entsprechen Bei einer nicht mit uns abgestimmten nderung der Pumpen ver liert diese Erkl rung Ihre G ltig...

Page 3: ...nung des Pumpengeh uses greifen W hrend des Betriebes der Pumpe d rfen sich Personen nicht im F rdermedium aufhalten Die Unfall verh tungsvorschriften sowie die allgemein anerkannten Regeln der Techn...

Page 4: ...setzt wird um ein Verkanten im Brunnenschacht beim Ablassen der Pumpe zu vermeiden 7 2 Montage Am Pumpengeh use wird eine Tragschelle befestigt und die Pumpe mit Hilfe eines Flaschenzuges soweit abge...

Page 5: ...ung Zus tzlich bei Pumpentypen mit lsperrkammer lstand und lzustand Pumpe horizontal legen so dass sich die lkammerschraube bei gr eren Pumpen eine der beiden lkammerschrauben oben befindet Die Schrau...

Page 6: ...d erfragen Sie bitte bei unserem 0 22 47 70 20 Kundendienst unter der Hotline f r Notf lle Telefonnummer 0 22 47 70 20 0 22 47 70 23 31 Auf das im beiliegenden Garantieschein beschriebene Produkt gew...

Page 7: ...in which they are marketed by us conform to the relevant fundamental safety and health requirements of the EC Machine Directives EC Directives to which the pumps conform EC Machinery Directive 98 37...

Page 8: ...iption 3 1 Applications If the pump is used for cleaning or maintenance of swimming pools make sure that no persons stay in the swimming pool during operation of the pump and that the pump is reliable...

Page 9: ...ossible over the dis charge Unlubricated operation leads in shortest time to the de struction of pump and motor In order to exclude this a switchgear with unlubricated operation protection s HOMA acce...

Page 10: ...erates but gives no liquid Discharge valve closed or blocked Check the discharge valve and possibly open and or clean Non return valve blocked Clean non return valve We grant for the described product...

Page 11: ...11...

Page 12: ...12...