Expansion  plugs  and  screws,  provided 

with  the  product,  are  only  suitable  for 

concrete or solid brick  walls. For different 

wall material types, use the appropriate 

fixing means.

INSTALLATION 

ELECTRICAL  

CONNECTIONS 

By means of the illuminated switch the 

radiator can be switched on and off.

USE OF THE PRODUCT   

Avoid using acid-based product. 

Do not use products containing 

sodium  hypochlorite,  chlorine-based 

detergents,  or  those  containing  bleach 

or aggressive solvents that are not 

suitable for the cleaning of painted 

surfaces. Do not use abrasive sponges.

In  the  event  of  overheating,  the  safety 

internal device automatically detaches 

the ceramic heater element. The radiator 

will start again to operate as soon as the 

temperature returns below the safety 

threshold.

CLEANING  

MALFUNCTION EVENTS

The product must be powered at a 

voltage of 230 Vac, 50 Hz.
The product is supplied, depending 

on type, with a Schuko plug cable to 

connect to a proper socket, or with a 3 

core cable for a permanent installation 

to the main power supply (Brown = Live, 

Blue = Neutral, Green/Yellow = Earth ).

Always make observe the minimum 

distances  from  wall,  furniture  or  other 

objects as showed (fig. A, pag 3).
The appliance has a grade IPX4 water 

protection. The product may be used in 

bathrooms or humid places as long as 

the safety zones are respected. In any 

cases avoid installing the appliance 

in location where there is a lot of 

condensation.
It must never be possible for person in 

the bath tub or shower to reach the 

power switch.

If malfunction operating is 

noted or the damaging of the 

panel  appear,  disconnect  the 

radiator from the main supply 

and contact the dealer.

Summary of Contents for Xilo L

Page 1: ...HOM COLLECTION ELECTRICAL RADIATOR INSTALLATION INSTRUCTION Pag 2 Xilo L ...

Page 2: ...1 ELECTRICAL APPLIANCE PROTECTION CLASS IP24 STANDARD REFERENCE EN60335 1 EN60335 2 30 TECHNICAL DATA DISEGNO TECNICO DATI TECNICI VOLTAGGIO 230 VOLT 50 Hz POTENZA NOMINALE Versioni da 500 Watt 700 Watt 1000 Watt CLASSE DI ISOLAMENTO 1 GRADO DI PROTEZIONE IP24 NORME DI RIFERIMENTO EN60335 1 EN60335 2 30 ...

Page 3: ...TALL ONLY IN ZONE 3 Fig A 3 3 ATTREZZATURA POSIZIONAMENTO SICURO Fig A INSTALLARE SOLO IN ZONA 3 3 ATTREZZATURA POSIZIONAMENTO SICURO Fig A INSTALLARE SOLO IN ZONA 3 3 ATTREZZATURA POSIZIONAMENTO SICURO Fig A INSTALLARE SOLO IN ZONA 3 ...

Page 4: ...4 INSTALLING 1 4 INSTALLAZIONE 1 2a VERSIONE CON CAVO SCHUKO 2a 4 INSTALLAZIONE 1 2a VERSIONE CON CAVO SCHUKO SCHUKO VERSION ...

Page 5: ...5 INSTALLING 2b b VERSIONE MURO WALL VERSION ...

Page 6: ...6 INSTALLING 2c 2c WALL VERSION ...

Page 7: ...7 INSTALLING 4 4 ...

Page 8: ...ation appliance and must be properly grounded If a product with Schuko plug is installed FOR YOUR SAFETY in France connect it to the main power supply by cutting off the plug and adopting a suitable connection box The electrical connection to the main power supply must also include a bipolar switch with a minimum contact aperture of 3 mm If the electric cable or the plug are damaged and has to be ...

Page 9: ...n as the temperature returns below the safety threshold CLEANING MALFUNCTION EVENTS The product must be powered at a voltage of 230 Vac 50 Hz The product is supplied depending on type with a Schuko plug cable to connect to a proper socket or with a 3 core cable for a permanent installation to the main power supply Brown Live Blue Neutral Green Yellow Earth Always make observe the minimum distances...

Page 10: ...Via Praglia 15 10044 Pianezza TO Italy tel fax 39 011 9678803 www homwarm com info homwarm com ...

Reviews: