TROUBLE SHOOTING
HOLZMANN MASCHINEN Austria www.holzmann-maschinen.at
Seite 40
STÄNDERBOHRMASCHINE / DRILL PRESS SB4115H/SB4115N/SB4116HM/SB4116HN
16
TROUBLE SHOOTING
BEFORE YOU START WORKING FOR THE ELIMINATION OF DEFECTS, DISCONNECT THE
MACHINE FROM THE POWER SUPPLY.
Fehler
Mögliche Ursache
Behebung
Motor does not run
Incorrect power supply
Let it be checked by a trained
person
Switch defect
Change
Motor defect
Change
Safety switch activated
Check the cover of motor pulley
(open?).
Loud noice when running
Incorrect belt tension
Adjust belt tension (1cm rule)
Drill runs erratically
Drill chuck not assembled
correctly to arbour or one of them
is dirty
Check and adjust.
Drill chuck jaws worn or damaged Change drill chucj
Spindle or boring is worn
Check and replace if nesessary
Drill is hot and smokes
Too fast speed for material being
drilled
Reduce speed
use lubricants
Motor runs but no rotation
or weak drilling power
Belt tension too low
Pulley belt diry, slippery
Tighten
Clean
MANY POTENTIAL SOURCES OF ERROR CAN BE CLEARED BY THE EXPERTLY
CONNECTION TO THE ELECTRICITY GRID.